Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPheromones Regulating Reproduction in Subsocial Beetles: Insights with References to Eusocial Insects    Next AbstractSimultaneous expression of both MAT loci in haploid cells suppresses mutations in yeast microtubule motor genes »

J Anal Toxicol


Title:"A simple, reliable method for the determination of chlorinated volatile organics in human breath and air using glass sampling tubes"
Author(s):Stein VB; Narang RS; Wilson L; Aldous KM;
Address:"New York State Department of Health, Wadsworth Center, Albany 12201-0509, USA"
Journal Title:J Anal Toxicol
Year:1996
Volume:20
Issue:3
Page Number:145 - 150
DOI: 10.1093/jat/20.3.145
ISSN/ISBN:0146-4760 (Print) 0146-4760 (Linking)
Abstract:"A method for determining chloroform, 1,1,1-trichloroethane, carbon tetrachloride, and trichloroethene in breath samples was developed. It consisted of collecting samples in 40-ml. glass-silanized tubes that were 16-in. long and had a 0.64-in. diameter. The ends tapered, resulting in a tube with a 1/4-in. diameter that was 1 3/4-in. long; each end had a shutoff valve attached. One end had a strip of rubber tube attached to the shutoff valve for collecting the breath sample, and the other end contained a 1/4-in. Swagelok nut with a rubber septum for withdrawing the sample. Samples were withdrawn using a pressure-lock, gastight syringe, and they were injected onto a gas chromatograph fitted with an electron-capture detector. The analytes were stable for at least 22 days in these tubes. The method detection limit was determined to be 0.03, 0.08, 0.04, and 0.04 pg/ml. for chloroform, 1,1,1-trichloroethane, carbon tetrachloride, and trichloroethene, respectively. Precision, based on 13 injections, was determined to be 13% for 0.09 pg chloroform, 13% for 0.21 pg 1,1,1-trichloroethane, 8% for 0.16 pg carbon tetrachloride, and 14% for 0.1 pg trichloroethene. In all, the proposed method is a sensitive and reliable one for determining volatile organic compounds in breath and a method that can also be applied to air sampling"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor *Breath Tests Carbon Tetrachloride/*analysis/metabolism Chloroform/*analysis/metabolism Chromatography, Gas Glass Humans Reference Standards Reproducibility of Results Solvents/*analysis/metabolism Specimen H;"
Notes:"MedlineStein, V B Narang, R S Wilson, L Aldous, K M eng England 1996/05/01 J Anal Toxicol. 1996 May-Jun; 20(3):145-50. doi: 10.1093/jat/20.3.145"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024