Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSingle-sided membrane introduction mass spectrometry for on-line determination of semi-volatile organic compounds in air    Next Abstract"Variation in Volatile Organic Compounds in native, synanthropic accessions and cultivars of the musk strawberry (Fragaria moschata Duchesne ex Weston)" »

Analyst


Title:Solid phase micro-extraction in a miniature ion trap mass spectrometer
Author(s):Riter LS; Meurer EC; Cotte-Rodriguez I; Eberlin MN; Cooks RG;
Address:"Chemistry Department, Purdue University, West Lafayette, IN 47907, USA"
Journal Title:Analyst
Year:2003
Volume:128
Issue:9
Page Number:1119 - 1122
DOI: 10.1039/b308292j
ISSN/ISBN:0003-2654 (Print) 0003-2654 (Linking)
Abstract:"Fiber introduction mass spectrometry (FIMS), a variation of solid-phase microextraction (SPME) and membrane introduction mass spectrometry (MIMS), is employed with a miniature mass spectrometer. The inlet system, constructed of commercially available vacuum parts, allows the direct introduction of the SPME needle vacuum chamber into the mass spectrometer. Thermal desorption of the analyte from the poly(dimethylsiloxane) (PDMS) coated fiber was achieved with a built in nichrome heater, followed by electron ionization of the analytes internal to the cylindrical ion trap (CIT). The system has been tested with several volatile organic compounds (VOC) in air and to analyze the headspace over aqueous solutions, with limits of detection in the low ppb range. The signal rise (10-90%) and fall (90-10%) times for the system ranged from 0.1 to 1 s (rise) and 1.2 to 6 s (fall) using heated desorption. In addition, this method has been applied to quantitation of toluene in benzene, toluene, xylene (BTX) mixtures in water and gasoline. This simple and rapid analysis method, coupled to a portable mass spectrometer, has been shown to provide a robust, simple, rapid, reproducible, accurate and sensitive (low ppb range) fieldable approach to the effective in situ analysis of VOC in various matrices"
Keywords:Ions Mass Spectrometry/*instrumentation/methods Microchemistry Organic Chemicals/*analysis;
Notes:"MedlineRiter, Leah S Meurer, Eduardo C Cotte-Rodriguez, Ismael Eberlin, Marcos N Cooks, R Graham eng Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. England 2003/10/08 Analyst. 2003 Sep; 128(9):1119-22. doi: 10.1039/b308292j"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-11-2024