Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPheromones: the scent of a male    Next AbstractSynomone or kairomone?--Bulbophyllum apertum flower releases raspberry ketone to attract Bactrocera fruit flies »

Molecules


Title:Optimization of Time-Weighted Average Air Sampling by Solid-Phase Microextraction Fibers Using Finite Element Analysis Software
Author(s):Kenessov B; Koziel JA; Baimatova N; Demyanenko OP; Derbissalin M;
Address:"Center of Physical Chemical Methods of Research and Analysis, Al-Farabi Kazakh National University, Almaty 050012, Kazakhstan. bkenesov@cfhma.kz. Department of Agricultural and Biosystems Engineering, Iowa State University, Ames, IA 50011, USA. koziel@iastate.edu. Center of Physical Chemical Methods of Research and Analysis, Al-Farabi Kazakh National University, Almaty 050012, Kazakhstan. baimatova@cfhma.kz. Center of Physical Chemical Methods of Research and Analysis, Al-Farabi Kazakh National University, Almaty 050012, Kazakhstan. demyanenko@cfhma.kz. Center of Physical Chemical Methods of Research and Analysis, Al-Farabi Kazakh National University, Almaty 050012, Kazakhstan. derbissalin@cfhma.kz"
Journal Title:Molecules
Year:2018
Volume:20181023
Issue:11
Page Number: -
DOI: 10.3390/molecules23112736
ISSN/ISBN:1420-3049 (Electronic) 1420-3049 (Linking)
Abstract:"Determination of time-weighted average (TWA) concentrations of volatile organic compounds (VOCs) in air using solid-phase microextraction (SPME) is advantageous over other sampling techniques, but is often characterized by insufficient accuracies, particularly at longer sampling times. Experimental investigation of this issue and disclosing the origin of the problem is problematic and often not practically feasible due to high uncertainties. This research is aimed at developing the model of the TWA extraction process and optimization of TWA air sampling by SPME using finite element analysis software (COMSOL Multiphysics, Burlington, MA, USA). It was established that sampling by porous SPME coatings with high affinity to analytes is affected by slow diffusion of analytes inside the coating, an increase of their concentrations in the air near the fiber tip due to equilibration, and eventual lower sampling rate. The increase of a fiber retraction depth (Z) resulted in better recoveries. Sampling of studied VOCs using 23 ga Carboxen/polydimethylsiloxane (Car/PDMS) assembly at maximum possible Z (40 mm) was proven to provide more accurate results. Alternative sampling configuration based on 78.5 x 0.75 mm internal diameter SPME liner was proven to provide similar accuracy at improved detection limits. Its modification with the decreased internal diameter from the sampling side should provide even better recoveries. The results obtained can be used to develop a more accurate analytical method for determination of TWA concentrations of VOCs in air using SPME. The developed model can be used to simulate sampling of other environments (process gases, water) by retracted SPME fibers"
Keywords:Air/*analysis Environmental Monitoring *Finite Element Analysis *Software *Solid Phase Microextraction Volatile Organic Compounds/*analysis Comsol air analysis air sampling solid-phase microextraction time-weighted average volatile organic compounds;
Notes:"MedlineKenessov, Bulat Koziel, Jacek A Baimatova, Nassiba Demyanenko, Olga P Derbissalin, Miras eng AP05133158/Ministry of Education and Science of the Republic of Kazakhstan/ IOW05400/Iowa Agriculture and Home Economics Experiment Station, Ames, Iowa/ Switzerland 2018/10/27 Molecules. 2018 Oct 23; 23(11):2736. doi: 10.3390/molecules23112736"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-11-2024