Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPersistence of transferred fragrance on fabrics for forensic reconstruction applications    Next AbstractOrigin of volatile organic compound emissions from subarctic tundra under global warming »

J Sep Sci


Title:Use of volatile organic solvents in headspace liquid-phase microextraction by direct cooling of the organic drop using a simple cooling capsule
Author(s):Ghiasvand AR; Yazdankhah F; Hajipour S;
Address:"Department of Chemistry, Lorestan University, Khoramabad, Iran"
Journal Title:J Sep Sci
Year:2016
Volume:39
Issue:15
Page Number:3011 - 3018
DOI: 10.1002/jssc.201600142
ISSN/ISBN:1615-9314 (Electronic) 1615-9306 (Linking)
Abstract:"A low-cost and simple cooling-assisted headspace liquid-phase microextraction device for the extraction and determination of 2,6,6-trimethyl-1,3 cyclohexadiene-1-carboxaldehyde (safranal) in Saffron samples, using volatile organic solvents, was fabricated and evaluated. The main part of the cooling-assisted headspace liquid-phase microextraction system was a cooling capsule, with a Teflon microcup to hold the extracting organic solvent, which is able to directly cool down the extraction phase while the sample matrix is simultaneously heated. Different experimental factors such as type of organic extraction solvent, sample temperature, extraction solvent temperature, and extraction time were optimized. The optimal conditions were obtained as: extraction solvent, methanol (10 muL); extraction temperature, 60 degrees C; extraction solvent temperature, 0 degrees C; and extraction time, 20 min. Good linearity of the calibration curve (R(2) = 0.995) was obtained in the concentration range of 0.01-50.0 mug/mL. The limit of detection was 0.001 mug/mL. The relative standard deviation for 1.0 mug/mL of safranal was 10.7% (n = 6). The proposed cooling-assisted headspace liquid-phase microextraction device was coupled (off-line) to high-performance liquid chromatography and used for the determination of safranal in Saffron samples. Reasonable agreement was observed between the results of the cooling-assisted headspace liquid-phase microextraction high-performance liquid chromatography method and those obtained by a validated ultrasound-assisted solvent extraction procedure"
Keywords:Capsules/chemistry *Cold Temperature Cyclohexenes/*analysis *Liquid Phase Microextraction Particle Size Solvents/chemistry Terpenes/*analysis Volatile Organic Compounds/*chemistry Cooling-assisted microextraction Headspace liquid-phase microextraction Hig;
Notes:"MedlineGhiasvand, Ali Reza Yazdankhah, Fatemeh Hajipour, Somayeh eng Germany 2016/06/18 J Sep Sci. 2016 Aug; 39(15):3011-8. doi: 10.1002/jssc.201600142"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024