Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCharacterization of infrared chemical sensors modified with ZnO nanowires for the detection of volatile organic compounds    Next AbstractElectro-scrubbing volatile organic carbons in the air stream with a gas diffusion electrode »

Analyst


Title:Membrane-introduced infrared spectroscopic chemical sensing method for the detection of volatile organic compounds in aqueous solutions
Author(s):Yang J; Ramesh A;
Address:"Department of Chemistry, National Chung-Hsing University, Taichung, Taiwan 402. jyisy@dragon.nchu.edu.tw"
Journal Title:Analyst
Year:2005
Volume:20050117
Issue:3
Page Number:397 - 403
DOI: 10.1039/b412421a
ISSN/ISBN:0003-2654 (Print) 0003-2654 (Linking)
Abstract:"A novel membrane-introduced infrared (IR) chemical sensing method has been developed for the detection of volatile organic compounds (VOCs) in aqueous solutions. In this method, a porous Teflon membrane was used to eliminate the problems associated with conventional IR spectroscopic sensing methods. The porous Teflon membrane was sealed below an IR spectroscopic sensing element pre-coated with a hydrophobic film and a two-channel flow cell configuration was established. In this configuration, the aqueous sample was allowed to pass through the lower channel and the VOCs that penetrated through the membrane to the upper channel were detected by the IR sensor. In this manner, the performance of the sampling at the headspace was improved while the problems caused by the presence of water were eliminated. Meanwhile, using a purging channel allowed the sensing element to be regenerated rapidly and enabled automation of the detection process. The parameters that influenced the analytical signals were studied, such as the sampling flow rate, the pH and ionic strength of the sample solutions, the effect of the volatilities of the VOCs, and the regeneration efficiency of the sensing element. The results indicated that the analytical signals were insensitive to the sampling flow rate and to the pH and ionic strength of the sample solutions. The results obtained from the detection of seven different volatile compounds indicated that this method is highly suitable for the detection of organic compounds that have vapor pressures >1 Torr and that it is potentially usable for organic compounds that have vapor pressures between 20 mTorr and 1 Torr. The regression analysis of the standard curves indicated that a regression coefficient (R(2)) > 0.99 was obtainable in the concentration range from 1 to 100 microg mL(-1). The detection limits for the tested compounds were around a few hundred ng mL(-1)"
Keywords:"Hydrogen-Ion Concentration Organic Chemicals/*analysis Osmolar Concentration Spectroscopy, Fourier Transform Infrared/instrumentation/methods Volatilization Water Pollutants, Chemical/*analysis;"
Notes:"MedlineYang, Jyisy Ramesh, Attinti eng Research Support, Non-U.S. Gov't England 2005/02/23 Analyst. 2005 Mar; 130(3):397-403. doi: 10.1039/b412421a. Epub 2005 Jan 17"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024