Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Analytical strategies for the quality assessment of recycled high-impact polystyrene: a combination of thermal analysis, vibrational spectroscopy, and chromatography"    Next Abstract"Effect of salt reduction and inclusion of 1% edible seaweeds on the chemical, sensory and volatile component profile of reformulated frankfurters" »

J Chromatogr A


Title:Emission pattern of semi-volatile organic compounds from recycled styrenic polymers using headspace solid-phase microextraction gas chromatography-mass spectrometry
Author(s):Vilaplana F; Martinez-Sanz M; Ribes-Greus A; Karlsson S;
Address:"Department of Fibre and Polymer Technology, School of Chemical Science and Engineering, KTH-Royal Institute of Technology, Teknikringen 56-58, SE-10044 Stockholm, Sweden"
Journal Title:J Chromatogr A
Year:2010
Volume:20091120
Issue:3
Page Number:359 - 367
DOI: 10.1016/j.chroma.2009.11.057
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"The emission of low molecular weight compounds from recycled high-impact polystyrene (HIPS) has been investigated using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS). Four released target analytes (styrene, benzaldehyde, acetophenone, and 2-phenylpropanal) were selected for the optimisation of the HS-SPME sampling procedure, by analysing operating parameters such as type of SPME fibre (polarity and operating mechanism), particle size, extraction temperature and time. 26 different compounds were identified to be released at different temperatures from recycled HIPS, including residues of polymerisation, oxidated derivates of styrene, and additives. The type of SPME fibre employed in the sampling procedure affected the detection of emitted components. An adsorptive fibre such as carbowax/polydimethylsiloxane (CAR/PDMS fibre) offered good selectivity for both non-polar and polar volatile compounds at lower temperatures; higher temperatures result in interferences from less-volatile released compounds. An absorptive fibre as polydimethylsiloxane (PDMS) fibre is suitable for the detection of less-volatile non-polar molecules at higher temperatures. The nature and relative amount of the emitted compounds increased with higher exposure temperature and smaller polymeric particle size. HS-SPME proves to be a suitable technique for screening the emission of semi-volatile organic compounds (SVOCs) from polymeric materials; reliable quantification of the content of target analytes in recycled HIPS is however difficult due to the complex mass-transfer processes involved, matrix effects, and the difficulties in equilibrating the analytical system"
Keywords:Gas Chromatography-Mass Spectrometry/*methods Gases/chemistry Molecular Weight Particle Size Polystyrenes/*chemistry Solid Phase Microextraction/*methods Volatile Organic Compounds/*chemistry;
Notes:"MedlineVilaplana, Francisco Martinez-Sanz, Marta Ribes-Greus, Amparo Karlsson, Sigbritt eng Research Support, Non-U.S. Gov't Netherlands 2009/12/08 J Chromatogr A. 2010 Jan 15; 1217(3):359-67. doi: 10.1016/j.chroma.2009.11.057. Epub 2009 Nov 20"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-11-2024