Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"The genetic architecture of constitutive and induced trichome density in two new recombinant inbred line populations of Arabidopsis thaliana: phenotypic plasticity, epistasis, and bidirectional leaf damage response"    Next AbstractDual-guild herbivory disrupts predator-prey interactions in the field »

J Environ Monit


Title:"Methodology for collecting, storing, and analyzing human milk for volatile organic compounds"
Author(s):Blount BC; McElprang DO; Chambers DM; Waterhouse MG; Squibb KS; LaKind JS;
Address:"US Centers for Disease Control and Prevention, Division of Laboratory Sciences, National Center for Environmental Health, Atlanta, GA 30341, USA. bkb3@cdc.gov"
Journal Title:J Environ Monit
Year:2010
Volume:20100331
Issue:6
Page Number:1265 - 1273
DOI: 10.1039/b927022a
ISSN/ISBN:1464-0333 (Electronic) 1464-0325 (Linking)
Abstract:"Biomonitoring, or the measurement of environmental chemicals in human tissues and fluids, is used to supplement-and in some cases replace-more traditional exposure assessments which measure chemicals in environmental media. Volatile organic compounds (VOCs) in physiological fluids are biomarkers of exposure that present numerous challenges for sample collection and analysis. To date, a thorough evaluation of methods for collection and analysis of breast milk samples for volatiles has not been conducted. In this paper, we describe the development and validation of methods for collecting, storing, and analyzing 36 volatile organic compounds (VOCs) in breast milk to assess VOC exposure of lactating women and nursing infants. Volatile analyte loss was minimized by collecting and storing samples in containers with small headspace volume resulting in recovery >or=70% for all 10 VOCs detected in most breast milk samples. Potential contamination by chloroform, benzene, toluene, ethylbenzene, xylenes, and methyl-tert-butyl ether was minimized by using specially treated sample collection materials. Method detection limits in the low parts per trillion range were achieved by using solid-phase microextraction headspace sampling, gas chromatography, and selective ion monitoring mass spectrometry. We used this method to analyze 3 mL aliquots of breast milk collected from 12 women and found that 10 of the 36 VOCs were detectable in most samples (median values follow): m/p-xylene, 0.539 ng mL(-1); toluene, 0.464 ng mL(-1); 1,4-dichlorobenzene, 0.170 ng mL(-1); tetrachloroethylene, 0.165 ng mL(-1); o-xylene, 0.159 ng mL(-1); ethylbenzene, 0.0149 ng mL(-1); styrene, 0.129 ng mL(-1); benzene, 0.080 ng mL(-1); chloroform, 0.030 ng mL(-1); and methyl-tert-butyl ether, 0.016 ng mL(-1)"
Keywords:"Environmental Monitoring/*methods Environmental Pollutants/*metabolism Female Humans Milk, Human/*metabolism Volatile Organic Compounds/*metabolism;"
Notes:"MedlineBlount, Benjamin C McElprang, David O Chambers, David M Waterhouse, Michael G Squibb, Katherine S Lakind, Judy S eng Validation Study England 2010/04/02 J Environ Monit. 2010 Jun; 12(6):1265-73. doi: 10.1039/b927022a. Epub 2010 Mar 31"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-11-2024