Indoor Air


Title:Indoor air pollutant health prioritization in office buildings
Author(s):Serafin G; Blondeau P; Mandin C;
Address:"La Rochelle University, La Rochelle, France. Scientific and Technical Centre for Building (CSTB), Observatory of Indoor Air Quality (OQAI), Paris Est University, Paris, France"
Journal Title:Indoor Air
Year:2021
Volume:20201221
Issue:3
Page Number:646 - 659
DOI: 10.1111/ina.12776
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"This work presents an original method to identify priority indoor air pollutants in office buildings. It uses both a chronic risk assessment approach by calculating a hazard quotient, and a hazard classification method based on carcinogenic, mutagenic, reprotoxic, and endocrine disruptive effects. A graphical representation of the results provides a comprehensive and concise visualization of all of the information, including the number of buildings where each substance was measured, an indicator of exposure data robustness. Seventy-one out of 342 substances (20%) for which indoor air concentrations have already been measured in office buildings were identified as priority pollutants. The results were compared to previous prioritization studies in various types of indoor environments to assess the reliability of the method and highlight its advantages. Sensitivity analyses were performed to reduce the geographical scope (OECD countries only), time scope (after 2010 only), and measurement duration (working hours only) and showed little influence on the results. Finally, 123 additional substances that could be present in office indoor air but could not be assessed due to the lack of measurement data are proposed for future monitoring surveys to update the prioritization of indoor air pollutants in offices"
Keywords:"Air Pollutants Air Pollution, Indoor/*statistics & numerical data *Environmental Monitoring Humans Reproducibility of Results Risk Assessment Volatile Organic Compounds Iaq carcinogenicity endocrine disruption hazard quotient ranking;"
Notes:"MedlineSerafin, Guillaume Blondeau, Patrice Mandin, Corinne eng Research Support, Non-U.S. Gov't England 2020/12/22 Indoor Air. 2021 May; 31(3):646-659. doi: 10.1111/ina.12776. Epub 2020 Dec 21"

 