Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractInfluence of light availability and soil productivity on insect herbivory on bilberry (Vaccinium myrtillus L.) leaves following mammalian herbivory    Next AbstractCharacterization of particle emission from household electrical appliances »

Anal Bioanal Chem


Title:A microscale device for measuring emissions from materials for indoor use
Author(s):Schripp T; Nachtwey B; Toelke J; Salthammer T; Uhde E; Wensing M; Bahadir M;
Address:"Fraunhofer Wilhelm-Klauditz-Institute (WKI), Material Analysis and Indoor Chemistry, Bienroder Weg 54E, 38108 Braunschweig, Germany"
Journal Title:Anal Bioanal Chem
Year:2007
Volume:20070116
Issue:5
Page Number:1907 - 1919
DOI: 10.1007/s00216-006-1057-2
ISSN/ISBN:1618-2642 (Print) 1618-2642 (Linking)
Abstract:"Emission test chambers or cells are used to determine organic vapour emissions from construction products under controlled conditions. Polymeric car trim component emissions are typically evaluated using direct thermal desorption/extraction. The Microchamber/Thermal Extractor (mu-CTE, Markes International) was developed to provide both a complementary tool for rapid screening of volatile organic compound (VOC) emissions--suitable for industrial quality control--and a means for thermal extraction of larger, more representative samples of car trim components. To determine the degree of correlation between conventional emission test methods and the microchamber, experiments were carried out under different conditions of temperature, air change rate and sample conditioning time. Good quantitative and qualitative correlation was obtained for measurements at ambient temperature. Moreover, it was shown that ambient-temperature emissions data collected using the mu-CTE as rapidly as possible--i.e. with minimal or no sample conditioning time--nevertheless provided a reliable guide as to how well that material would perform in subsequent 3-day chamber tests of VOC emissions. The parameters found to have the greatest influence on data correlation for experiments carried out at elevated temperatures were the sample mass (for bulk emissions testing) and the conditioning time. The results also showed that, within the constraints of inherent sample homogeneity, the mu-CTE gave reproducible emissions data, despite its small sample size/capacity relative to that of conventional chambers. Preliminary results of modelling the air flow within a microchamber using computational fluid dynamics showed a high degree of turbulent flow and two potential areas of still air which could cause sink effects. However, the experimental data reported here and in previous studies showed enhanced recovery of semivolatile components from the mu-CTE relative to a recovery from a 1 m(3) conventional chamber. This indicates that if these areas of relatively still air are present within the microchamber, they do not appear to be significant in practice"
Keywords:
Notes:"PubMed-not-MEDLINESchripp, T Nachtwey, B Toelke, J Salthammer, T Uhde, E Wensing, M Bahadir, M eng Germany 2007/01/17 Anal Bioanal Chem. 2007 Mar; 387(5):1907-19. doi: 10.1007/s00216-006-1057-2. Epub 2007 Jan 16"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024