Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDemonstration of proton-transfer reaction time-of-flight mass spectrometry for real-time analysis of trace volatile organic compounds    Next AbstractInoculated fermentation of green olives with potential probiotic Lactobacillus pentosus and Lactobacillus plantarum starter cultures isolated from industrially fermented olives »

Rapid Commun Mass Spectrom


Title:High pressure mass spectrometry of volatile organic compounds with ambient air buffer gas
Author(s):Blakeman KH; Cavanaugh CA; Gilliland WM; Ramsey JM;
Address:"Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA. Department of Applied Physical Sciences, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA. Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA. Carolina Center for Genome Sciences, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA"
Journal Title:Rapid Commun Mass Spectrom
Year:2017
Volume:31
Issue:1
Page Number:27 - 32
DOI: 10.1002/rcm.7766
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Linking)
Abstract:"RATIONALE: There are many chemical measurement scenarios that would benefit from hand portable mass spectrometry tools including forensics, environmental monitoring, and safety and security. High pressure mass spectrometry (HPMS) facilitates miniaturization by significantly reducing vacuum system requirements. Previous work demonstrated HPMS using helium buffer gas, but HPMS conducted using ambient air would further reduce the size and weight of a portable instrument while also reducing logistical demands by eliminating the need for a helium supply. METHODS: Mass spectrometry was performed at pressures exceeding 1 Torr with ambient air as the buffer gas. A glow discharge electron ionization source and a miniature cylindrical ion trap mass analyzer with a radius of 0.5 mm were used. Mass analysis was possible at these pressures with increased radiofrequency (RF) drive frequencies (10 MHz) compared with commercial ion traps (~1 MHz). A differentially pumped chamber was used so that mass spectrometry could be performed at high pressures and detection performed at low pressures with an electron multiplier. RESULTS: HPMS with air buffer gas was demonstrated using a suite of volatile organic compounds (VOCs). The glow discharge ionization source was optimized for operation using air. Mass spectral peak widths increased a factor of 8 compared with helium, as expected, but useful chemical information was still acquired. A mixture of VOCs was detected with ambient air as the buffer gas, showing that valuable mass information can be gained using HPMS without the requirement of an onboard buffer gas source. CONCLUSIONS: HPMS significantly reduces the pumping requirements required for miniature mass spectrometers and the use of ambient air buffer gas further reduces size, weight, and logistics requirements. Mass analysis at high pressures of ambient air is another important step for the development of hand portable mass spectrometers. Copyright (c) 2016 John Wiley & Sons, Ltd"
Keywords:
Notes:"PubMed-not-MEDLINEBlakeman, Kenion H Cavanaugh, Craig A Gilliland, William M Jr Ramsey, J Michael eng England 2016/10/18 Rapid Commun Mass Spectrom. 2017 Jan 15; 31(1):27-32. doi: 10.1002/rcm.7766"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024