Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractHigh-Throughput Breath Volatile Organic Compound Analysis Using Thermal Desorption Proton Transfer Reaction Time-of-Flight Mass Spectrometry    Next AbstractExploring volatile organic compound emission from thermally modified wood by PTR-ToF-MS »

J Mass Spectrom


Title:"Identification and quantification of VOCs by proton transfer reaction time of flight mass spectrometry: An experimental workflow for the optimization of specificity, sensitivity, and accuracy"
Author(s):Romano A; Hanna GB;
Address:"Department Surgery and Cancer, Imperial College London, UK"
Journal Title:J Mass Spectrom
Year:2018
Volume:53
Issue:4
Page Number:287 - 295
DOI: 10.1002/jms.4063
ISSN/ISBN:1096-9888 (Electronic) 1076-5174 (Print) 1076-5174 (Linking)
Abstract:"Proton transfer reaction time of flight mass spectrometry (PTR-ToF-MS) is a direct injection MS technique, allowing for the sensitive and real-time detection, identification, and quantification of volatile organic compounds. When aiming to employ PTR-ToF-MS for targeted volatile organic compound analysis, some methodological questions must be addressed, such as the need to correctly identify product ions, or evaluating the quantitation accuracy. This work proposes a workflow for PTR-ToF-MS method development, addressing the main issues affecting the reliable identification and quantification of target compounds. We determined the fragmentation patterns of 13 selected compounds (aldehydes, fatty acids, phenols). Experiments were conducted under breath-relevant conditions (100% humid air), and within an extended range of reduced electric field values (E/N = 48-144 Td), obtained by changing drift tube voltage. Reactivity was inspected using H(3) O(+) , NO(+) , and O(2)(+) as primary ions. The results show that a relatively low (<90 Td) E/N often permits to reduce fragmentation enhancing sensitivity and identification capabilities, particularly in the case of aldehydes using NO(+) , where a 4-fold increase in sensitivity is obtained by means of drift voltage reduction. We developed a novel calibration methodology, relying on diffusion tubes used as gravimetric standards. For each of the tested compounds, it was possible to define suitable conditions whereby experimental error, defined as difference between gravimetric measurements and calculated concentrations, was 8% or lower"
Keywords:PTR-ToF-MS breath analysis ion chemistry method development volatile organic compounds;
Notes:"PubMed-not-MEDLINERomano, Andrea Hanna, George B eng England 2018/01/18 J Mass Spectrom. 2018 Apr; 53(4):287-295. doi: 10.1002/jms.4063"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024