Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractA new experimental method to determine the sorption isotherm of a liquid in a porous medium    Next AbstractAnalysis of volatile metabolite variations in strip green tea during processing and effect of rubbing degree using untargeted and targeted metabolomics »

J Occup Environ Hyg


Title:"Behavior of the GABIE, 3M 3500, PerkinElmer Tenax TA, and RADIELLO 145 diffusive samplers exposed over a long time to a low concentration of VOCs"
Author(s):Oury B; Lhuillier F; Protois JC; Morele Y;
Address:"Institut National de Recherche et de Securite - Metorologie des Polluants, Vandoeuvre-les-Nancy, France. benoit.oury@inrs.fr"
Journal Title:J Occup Environ Hyg
Year:2006
Volume:3
Issue:10
Page Number:547 - 557
DOI: 10.1080/15459620600906613
ISSN/ISBN:1545-9624 (Print) 1545-9624 (Linking)
Abstract:"Diffusive sampling is particularly suited to determine time-weighted average volatile organic compound (VOC) concentration in occupational hygiene and environmental air monitoring. The purpose of this study was to measure the sampling rate variation of four different samplers in a special use--the exposure to a low concentration of volatile organic compound (10 to 200 ppb) for a long period (1 to 14 days). PerkinElmer tube-type adsorbent was packed with Tenax TA and RADIELLO cartridge packed with Carbograph 4. Badge-type activated carbon diffusive samplers 3M 3500 and GABIE were exposed to the same controlled atmospheres of benzene as meta-xylene (BTX) during the same exposure times. Performance samplers were observed for variability of uptake rates according to concentration levels, exposure duration, back diffusion, and competition phenomena at the adsorption sites. Particular benzene behavior has been noted for the thermally desorbable tube-type diffusive sampler: the measured sampling rates decrease with time following an exponential profile. With badge-type active charcoal diffusive samplers, the uptake rates were found to be highly stable and unaffected by time exposure. Overall, in the region of a few tens of ppb, for long-time exposure and for the lightest compounds, 3M 3500 and GABIE diffusive samplers seem the most appropriate diffusive sampling technique in terms of performance and facility in use"
Keywords:Adsorption Air Pollutants/analysis/chemistry Benzene/analysis/chemistry Environmental Monitoring/*instrumentation/methods Equipment and Supplies/standards Toluene/analysis/chemistry Xylenes/analysis/chemistry;
Notes:"MedlineOury, Benoit Lhuillier, Francine Protois, Jean-Claude Morele, Yves eng Comparative Study Evaluation Study England 2006/08/16 J Occup Environ Hyg. 2006 Oct; 3(10):547-57. doi: 10.1080/15459620600906613"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024