Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBrook char (Salvelinus fontinalis) can differentiate chemical alarm cues produced by different age/size classes of conspecifics    Next AbstractMathematical modeling and experimental study of VOC adsorption by Pistachio shell-based activated carbon »

ACS Appl Mater Interfaces


Title:A Microwave Voyage into Swelling Phenomenon: Investigation of Polydimethylsiloxane and VOCs Interaction
Author(s):Mirzaei H; McClelland J; Sharma D; Arjmand M; Zarifi MH;
Address:"School of Engineering, University of British Columbia, Okanagan Campus, Kelowna, Canada V1V 1V7"
Journal Title:ACS Appl Mater Interfaces
Year:2023
Volume:20230731
Issue:31
Page Number:38008 - 38017
DOI: 10.1021/acsami.3c05318
ISSN/ISBN:1944-8252 (Electronic) 1944-8244 (Linking)
Abstract:"When exposed to specific gases, polymers undergo swelling, leading to physiochemical changes that can significantly affect their performance. Monitoring this swelling phenomenon requires innovative approaches. This study focuses on investigating the real-time resonant microwave behavior of two polydimethylsiloxane (PDMS) structures (solid and porous) in interaction with tetrahydrofuran (THF) and acetone, which are primary swelling agents. A microwave measurement method is proposed using an 8.63 GHz planar split ring resonator (SRR). The device's resonant frequency downshifts to 7.75 and 8.42 GHz when solid and porous PDMS blocks are placed on the split ring gap. Interaction of the solid PDMS and porous PDMS with target gases caused a change in PDMS structure resulting in alterations in the dielectric properties of the PDMS/gas system, as evidenced by the resonator's transmission amplitude and resonant frequency shifts. The magnitude of these shifts depends on the type and concentration of the solvent gas. The PDMS-integrated SRR exhibits a sensitivity of 25.3 MHz/1 ppt THF and 7 MHz/1 ppt acetone. Additionally, the solid block demonstrates response times of 6800 and 4200 s for swelling and deswelling, respectively, when in exposure to 25 ppt concentrations of THF and acetone. Overall, this study underscores the substantial potential of microwave resonators as versatile tools for investigating the physical changes in polymers during their interaction with gases, contributing to the understanding of polymer-gas interactions and opening avenues for further research and diverse applications"
Keywords:gas monitoring microwave polydimethylsiloxane split ring resonator swelling volatile organic compounds;
Notes:"PubMed-not-MEDLINEMirzaei, Hamed McClelland, Jack Sharma, Devansh Arjmand, Mohammad Zarifi, Mohammad H eng 2023/07/31 ACS Appl Mater Interfaces. 2023 Aug 9; 15(31):38008-38017. doi: 10.1021/acsami.3c05318. Epub 2023 Jul 31"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024