Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDiagnostic potential of the pulsed discharged helium ionization detector (PDHID) for pathogenic Mycobacterial volatile biomarkers    Next AbstractCreosote bush (Larrea tridentata) resin increases water demands and reduces energy availability in desert woodrats (Neotoma lepida) »

Anal Sci


Title:Development of a Mesoscale Pulsed Discharge Helium Ionization Detector for Portable Gas Chromatography
Author(s):Manginell RP; Mowry CD; Pimentel AS; Mangan MA; Moorman MW; Sparks ES; Allen A; Achyuthan KE;
Address:"Bio/Chem/Physical Microsensors Department, Sandia National Laboratories"
Journal Title:Anal Sci
Year:2015
Volume:31
Issue:11
Page Number:1183 - 1188
DOI: 10.2116/analsci.31.1183
ISSN/ISBN:1348-2246 (Electronic) 0910-6340 (Linking)
Abstract:"Miniaturization of gas chromatography (GC) instrumentation enables field detection of volatile organic compounds (VOCs) for chembio-applications such as clandestine human transport and disease diagnostics. We fabricated a mesoscale pulsed discharge helium ionization detector (micro-PDHID) for integrating with our previously described mini-GC hardware. Stainless steel electrodes fabricated by photochemical etching and electroforming facilitated rapid prototyping and enabled nesting of inter-electrode insulators for self-alignment of the detector core during assembly. The prototype was approximately 10 cm(3) relative to >400 cm(3) of a commercial PDHID, but with a comparable time to sweep a VOC peak from the detector cell (170 ms and 127 ms, respectively). Electron trajectory modeling, gas flow rate, voltage bias, and GC outlet location were optimized for improving sensitivity. Despite 40-fold miniaturization, the micro-PDHID detected 18 ng of the human emanation, 3-methyl-2-hexenoic acid with <3-fold decrease in sensitivity relative to the commercial detector. The micro-PDHID was rugged and operated for 9 months without failure"
Keywords:"Caproates/analysis Chromatography, Gas/*instrumentation Electrodes Helium/*chemistry Humans Miniaturization Stainless Steel;"
Notes:"MedlineManginell, Ronald P Mowry, Curtis D Pimentel, Adam S Mangan, Michael A Moorman, Matthew W Sparks, Elizabeth S Allen, Amy Achyuthan, Komandoor E eng Research Support, U.S. Gov't, Non-P.H.S. Switzerland 2015/11/13 Anal Sci. 2015; 31(11):1183-8. doi: 10.2116/analsci.31.1183"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024