Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDemonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors    Next Abstract"Determination of the volatile composition in brown millet, milled millet and millet bran by gas chromatography/mass spectrometry" »

Anal Chem


Title:Adaptive two-dimensional microgas chromatography
Author(s):Liu J; Khaing Oo MK; Reddy K; Gianchandani YB; Schultz JC; Appel HM; Fan X;
Address:"Department of Biomedical Engineering, University of Michigan, 1101 Beal Avenue, Ann Arbor, Michigan 48109, USA"
Journal Title:Anal Chem
Year:2012
Volume:20120410
Issue:9
Page Number:4214 - 4220
DOI: 10.1021/ac300588z
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"We proposed and investigated a novel adaptive two-dimensional (2-D) microgas chromatography system, which consists of one 1st-dimensional column, multiple parallel 2nd-dimensional columns, and a decision-making module. The decision-making module, installed between the 1st- and 2nd-dimensional columns, normally comprises an on-column nondestructive vapor detector, a flow routing system, and a computer that monitors the detection signal from the detector and sends out the trigger signal to the flow routing system. During the operation, effluents from the 1st-dimensional column are first detected by the detector and, then, depending on the signal generated by the detector, routed to one of the 2nd-dimensional columns sequentially for further separation. As compared to conventional 2-D GC systems, the proposed adaptive GC scheme has a number of unique and advantageous features. First and foremost, the multiple parallel columns are independent of each other. Therefore, their length, stationary phase, flow rate, and temperature can be optimized for best separation and maximal versatility. In addition, the adaptive GC significantly lowers the thermal modulator modulation frequency and hence power consumption. Finally, it greatly simplifies the postdata analysis process required to reconstruct the 2-D chromatogram. In this paper, the underlying working principle and data analysis of the adaptive GC was first discussed. Then, separation of a mixture of 20 analytes with various volatilities and polarities was demonstrated using an adaptive GC system with a single 2nd-dimensional column. Finally, an adaptive GC system with dual 2nd-dimensional columns was employed, in conjunction with temperature ramping, in a practical application to separate a mixture of plant emitted volatile organic compounds with significantly shortened analysis time"
Keywords:"Chromatography, Gas/*instrumentation Equipment Design Volatile Organic Compounds/*isolation & purification Volatilization;"
Notes:"MedlineLiu, Jing Khaing Oo, Maung Kyaw Reddy, Karthik Gianchandani, Yogesh B Schultz, Jack C Appel, Heidi M Fan, Xudong eng Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. 2012/04/04 Anal Chem. 2012 May 1; 84(9):4214-20. doi: 10.1021/ac300588z. Epub 2012 Apr 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024