Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEBR and JA regulate aroma substance biosynthesis in 'Ruidu Hongyu' grapevine berries by transcriptome and metabolite combined analysis    Next AbstractExpression and functional analysis of an odorant binding protein PopeOBP16 from Phthorimaea operculella (Zeller) »

ACS Sens


Title:"Electronic Nose Development and Preliminary Human Breath Testing for Rapid, Non-Invasive COVID-19 Detection"
Author(s):Li J; Hannon A; Yu G; Idziak LA; Sahasrabhojanee A; Govindarajan P; Maldonado YA; Ngo K; Abdou JP; Mai N; Ricco AJ;
Address:"NASA Ames Research Center, Moffett Field, California 94035, United States. Variable, Inc., Chattanooga, Tennessee 37406, United States. School of Medicine, Stanford University, Stanford, California 94305, United States"
Journal Title:ACS Sens
Year:2023
Volume:20230524
Issue:6
Page Number:2309 - 2318
DOI: 10.1021/acssensors.3c00367
ISSN/ISBN:2379-3694 (Electronic) 2379-3694 (Linking)
Abstract:"We adapted an existing, spaceflight-proven, robust 'electronic nose' (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using 'leave-one-out' training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home"
Keywords:Animals Humans Electronic Nose Reproducibility of Results *COVID-19/diagnosis *Nanostructures Breath Tests/methods *Volatile Organic Compounds/analysis Mammals Covid-19 infection detection nanomaterial sensor array;
Notes:"MedlineLi, Jing Hannon, Ami Yu, George Idziak, Luke A Sahasrabhojanee, Adwait Govindarajan, Prasanthi Maldonado, Yvonne A Ngo, Khoa Abdou, John P Mai, Nghia Ricco, Antonio J eng 2023/05/24 ACS Sens. 2023 Jun 23; 8(6):2309-2318. doi: 10.1021/acssensors.3c00367. Epub 2023 May 24"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-11-2024