Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Accelerated evolution of CES7, a gene encoding a novel major urinary protein in the cat family"    Next AbstractIdentification of Putative Olfactory Genes from the Oriental Fruit Moth Grapholita molesta via an Antennal Transcriptome Analysis »

J Sep Sci


Title:Determination of the volatiles from tobacco by capillary gas chromatography with atomic emission detection and mass spectrometry
Author(s):Li G; Wu D; Wang Y; Xie W; Zhang X; Liu B;
Address:"Department of Chemistry, Fudan University, Shanghai, P. R. China; Technology Center, Shanghai Tobacco Group Co., Ltd, Shanghai, P. R. China"
Journal Title:J Sep Sci
Year:2012
Volume:20111219
Issue:2
Page Number:334 - 340
DOI: 10.1002/jssc.201100732
ISSN/ISBN:1615-9314 (Electronic) 1615-9306 (Linking)
Abstract:"A new gas chromatograph-atomic emission detector (GC-AED) coupled with Deans switching technique for analyzing volatiles from tobaccos were developed. The detector operating parameters (reagent gas pressure and make-up gas flow rate) were optimized. The detection limits for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) ranged 0.05-0.2, 0.05-0.3 and 1-11 ng, respectively, depending on the compound. The sensitivity and linearity for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) decreased in the order O>H>C. Calibration curves were obtained by plotting peak area versus concentration, and the correlation coefficients relating to linearity were at least 0.9359. Elemental response factors measured on these channels, relative to the carbon 193-nm channel, were hydrogen, 0.38-0.48 (mean %RSD=5.64), and oxygen, 0.085-0.128 (mean %RSD=14.9). The evaluation was also done for the new technique and for an established GC-MS technique for the same real samples. The results of GC-AED and GC-MS showed that there was a relatively good agreement between the two sets of data"
Keywords:"Gas Chromatography-Mass Spectrometry/*methods Limit of Detection Spectrophotometry, Atomic/methods Tobacco/*chemistry Volatile Organic Compounds/*analysis Deans switching Elemental response factors Gc-aed;"
Notes:"MedlineLi, Gang Wu, Da Wang, Ye Xie, Wenyan Zhang, Xiangmin Liu, Baizhan eng Research Support, Non-U.S. Gov't Germany 2011/12/20 J Sep Sci. 2012 Jan; 35(2):334-40. doi: 10.1002/jssc.201100732. Epub 2011 Dec 19"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024