Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAlcohol vapours sensor based on thin polyaniline salt film and quartz crystal microbalance    Next AbstractEvolution of reproductive strategies in the sexually deceptive orchid Ophrys sphegodes: how does flower-specific variation of odor signals influence reproductive success? »

Anal Chim Acta


Title:Influence of humidity on accuracy of QCM - IR780-based GUMBOS sensor arrays
Author(s):Ayala CE; Vaughan SR; Perez RL; Leonard BS; King B; Jorgensen K; Warner IM;
Address:"Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA. Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA; Department of Chemistry and Biochemistry, Georgia Southern University, Statesboro, GA, 30458, USA. Electronic address: rperez@georgiasouthern.edu. Department of Chemistry and Biochemistry, Georgia Southern University, Statesboro, GA, 30458, USA. Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA. Electronic address: iwarner@lsu.edu"
Journal Title:Anal Chim Acta
Year:2023
Volume:20230816
Issue:
Page Number:341677 -
DOI: 10.1016/j.aca.2023.341677
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"Herein, hydrophobic coating materials are reported for QCM detection of VOCs under dry and humid conditions. In this study, IR780-based GUMBOS ([IR780][OTf] and [IR780][NTf2]) were synthesized using an ion exchange reaction and the anions trifluoromethanesulfonimide ([OTf]) and bisperfluoromethanesulfonimide ([NTf2]). The parent iodide salts and GUMBOS ([IR780][I]), [IR780][OTf], and [IR780][NTf2]) were characterized using several analytical techniques. These salts were then employed as sensor coatings on quartz crystal resonators using an electrospray coating method. These sensors were exposed to four flow ratios of five common VOCs in the absence and presence of 10 vol% water. Fundamental frequency responses were recorded and further employed as input variables to develop highly accurate multi-sensor arrays (MSAs). Accuracy was better than 78.3% without water, and better than 91.7% in the presence of water. When multi-harmonic responses were evaluated as input variables to assess discrimination ability for each sensor, highly accurate virtual sensor arrays (VSAs) were developed using each GUMBOS coating. In the case of [IR780][NTf2], a slight improvement in discrimination was achieved in the presence of water (95%) versus the absence of water. Moreover, this study highlights development of readily synthesized hydrophobic coatings of IR780-based GUMBOS for potential detection and discrimination of VOCs in aqueous systems"
Keywords:Gumbos Multi-sensor arrays (MSAs) Quartz crystal microbalance (QCM) Virtual sensor arrays (VSAs) Volatile organic compounds (VOCs);
Notes:"PubMed-not-MEDLINEAyala, Caitlan E Vaughan, Stephanie R Perez, Rocio L Leonard, Breona S King, Baleigh Jorgensen, Kyle Warner, Isiah M eng Netherlands 2023/09/15 Anal Chim Acta. 2023 Oct 16; 1278:341677. doi: 10.1016/j.aca.2023.341677. Epub 2023 Aug 16"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 15-11-2024