Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractInfluence of the inlet air in efficiency of photocatalytic devices for mineralization of VOCs in air-conditioning installations    Next AbstractLongitudinal two-dimensional gas chromatography mass spectrometry as a non-destructive at-line monitoring tool during cell manufacturing identifies volatile features correlative to cell product quality »

J Chromatogr A


Title:Carbon nanocones/disks as new coating for solid-phase microextraction
Author(s):Jimenez-Soto JM; Cardenas S; Valcarcel M;
Address:"Department of Analytical Chemistry, Marie Curie Building(Annex), Campus de Rabanales, University of Cordoba, E-14071 Cordoba, Spain"
Journal Title:J Chromatogr A
Year:2010
Volume:20100318
Issue:20
Page Number:3341 - 3347
DOI: 10.1016/j.chroma.2010.03.016
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"In this article, the potential of carbon nanocones/disks as coating for solid-phase microextraction has been evaluated for the first time. The nanostructures were immobilized on a stainless steel needle by means of an organic binder. The fiber coating obtained was ca. 50 microm of thickness and 35 mm in length. The evaluation of the sorbent capacity was carried out through the determination of toluene, ethylbenzene, xylene isomers and styrene in water samples following the headspace sampling modality (15 min, 30 degrees C). The fiber was then transferred to a 10 mL vial which was sealed and heated at 110 degrees C for 15 min in the headspace module of the instrument to achieve the thermal desorption of the analytes. Then 2.5 mL of the headspace generated were injected in the gas chromatograph-mass spectrometer for analytes separation and quantitation. The detection and quantitation limits obtained for 10 mL of sample were 0.15 and 0.5 ng mL(-1) (0.6 and 2 ng mL(-1) for toluene). The optimized procedure was applied to the determination of the selected volatile compounds in waters collected from different locations. The recovery values obtained (average recovery ca. 92%) demonstrated the usefulness of the carbon nanocones/disks as sorbent material in solid-phase microextraction"
Keywords:Adsorption Benzene Derivatives/chemistry Carbon/*chemistry Gas Chromatography-Mass Spectrometry Nanostructures/*chemistry Nanotechnology/methods Solid Phase Microextraction/*methods Toluene/chemistry Volatile Organic Compounds/chemistry Water/analysis Xyl;
Notes:"MedlineJimenez-Soto, Juan Manuel Cardenas, Soledad Valcarcel, Miguel eng Research Support, Non-U.S. Gov't Netherlands 2010/04/07 J Chromatogr A. 2010 May 14; 1217(20):3341-7. doi: 10.1016/j.chroma.2010.03.016. Epub 2010 Mar 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-11-2024