Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFig volatile compounds--a first comparative study    Next AbstractDetermination of the reaction yield during biotransformation of the volatile and chemically unstable compound beta-ionone by aspergillus niger »

J Chromatogr A


Title:Bridging the gap between gas and liquid chromatography
Author(s):Gritti F; Fogwill M; Gilar M; Jarrell JA;
Address:"Waters Corporation, Instrument/Core Research/Fundamental, Milford, MA 01757, USA. Electronic address: Fabrice_Gritti@waters.com. Waters Corporation, Instrument/Core Research/Fundamental, Milford, MA 01757, USA"
Journal Title:J Chromatogr A
Year:2016
Volume:20161018
Issue:
Page Number:107 - 116
DOI: 10.1016/j.chroma.2016.10.038
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"The rapid and complete baseline separation of both volatile (C(5) to C(16) alkanes in gasoline or terpenes in plant extracts) and non-volatile (>C(20) alkanes) organic compounds was achieved by combining (1) low-density fluid chromatography (LDFC) using carbon dioxide at elevated temperature (>90 degrees C) and low pressure (1500psi) designed to increase the retention of the most volatile compounds and (2) high-vacuum technology (<10(-4)Torr) in order to preserve the maximum efficiency of short analytical columns (3.0mmx150mm packed with 1.8mum fully porous HSS-SB-C(18) particles) when used in LDFC. The volatile compounds are eluted first under isobaric conditions (1500psi) in less than a minute followed by a linear gradient of the column back pressure (from 1500 to 3500psi in 5min) for the elution of the non-volatile compounds up to C(40). The experimental results demonstrate that LDFC performed with short 3.0mm i.d. columns packed with sub-2mum particles and placed under adiabatic conditions enables the analysts to deliver a single, fast, and high-resolution separation of both volatile and non-volatile compounds"
Keywords:"Alkanes/chemistry/*isolation & purification Cannabis/chemistry Carbon Dioxide/chemistry Chromatography, Liquid/*methods Gases/chemistry/*isolation & purification Gasoline/analysis Plant Extracts/chemistry Porosity Pressure Temperature Terpenes/chemistry/*;"
Notes:"MedlineGritti, Fabrice Fogwill, Michael Gilar, Martin Jarrell, Joseph A eng Netherlands 2016/10/25 J Chromatogr A. 2016 Nov 11; 1472:107-116. doi: 10.1016/j.chroma.2016.10.038. Epub 2016 Oct 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 24-11-2024