Title: | Hyphenated Mass Spectrometry versus Real-Time Mass Spectrometry Techniques for the Detection of Volatile Compounds from the Human Body |
Author(s): | Gould O; Drabinska N; Ratcliffe N; de Lacy Costello B; |
Address: | "Centre for Research in Biosciences, Frenchay Campus, University of the West of England, Coldharbour Lane, Bristol BS16 1QY, UK. Department of Chemistry and Biodynamics of Food, Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, 10-748 Olsztyn, Poland. Food Volatilomics and Sensomics Group, Faculty of Food Science and Nutrition, Poznan University of Life Sciences, 60-637 Poznan, Poland" |
DOI: | 10.3390/molecules26237185 |
ISSN/ISBN: | 1420-3049 (Electronic) 1420-3049 (Linking) |
Abstract: | "Mass spectrometry (MS) is an analytical technique that can be used for various applications in a number of scientific areas including environmental, security, forensic science, space exploration, agri-food, and numerous others. MS is also continuing to offer new insights into the proteomic and metabolomic fields. MS techniques are frequently used for the analysis of volatile compounds (VCs). The detection of VCs from human samples has the potential to aid in the diagnosis of diseases, in monitoring drug metabolites, and in providing insight into metabolic processes. The broad usage of MS has resulted in numerous variations of the technique being developed over the years, which can be divided into hyphenated and real-time MS techniques. Hyphenated chromatographic techniques coupled with MS offer unparalleled qualitative analysis and high accuracy and sensitivity, even when analysing complex matrices (breath, urine, stool, etc.). However, these benefits are traded for a significantly longer analysis time and a greater need for sample preparation and method development. On the other hand, real-time MS techniques offer highly sensitive quantitative data. Additionally, real-time techniques can provide results in a matter of minutes or even seconds, without altering the sample in any way. However, real-time MS can only offer tentative qualitative data and suffers from molecular weight overlap in complex matrices. This review compares hyphenated and real-time MS methods and provides examples of applications for each technique for the detection of VCs from humans" |
Keywords: | Human Body Humans *Mass Spectrometry *Proteomics Volatile Organic Compounds/*isolation & purification/metabolism Gc-ms Ptr-ms Sesi-ms Sift-ms chromatography mass spectrometry; |
Notes: | "MedlineGould, Oliver Drabinska, Natalia Ratcliffe, Norman de Lacy Costello, Ben eng Review Switzerland 2021/12/11 Molecules. 2021 Nov 26; 26(23):7185. doi: 10.3390/molecules26237185" |