Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatility of atmospherically relevant alkylaminium carboxylate salts    Next AbstractValidation studies of thermal extraction-GC/MS applied to source emissions aerosols. 1. Semivolatile analyte-nonvolatile matrix interactions »

J Chromatogr A


Title:Selective pressurised liquid extraction of halogenated pesticides and polychlorinated biphenyls from pine needles
Author(s):Lavin KS; Hageman KJ;
Address:"Department of Chemistry, University of Otago, Dunedin 9016, New Zealand"
Journal Title:J Chromatogr A
Year:2012
Volume:20120817
Issue:
Page Number:30 - 36
DOI: 10.1016/j.chroma.2012.08.042
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"Pine needles are an ideal matrix for the long-term monitoring of semi-volatile organic compounds in the atmosphere because they are naturally occurring and distributed worldwide. However, typical extraction methods result in the co-elution of matrix-interfering compounds and thus require time-consuming clean-up steps. A selective pressurised liquid extraction method (S-PLE) for extracting current-use pesticides, historic-use pesticides and polychlorinated biphenyls (PCBs) from pine needles that does not require additional clean-up steps was developed and validated. The selective extraction was achieved by packing the extraction vessel with a fat retainer, Florisil, down-stream of the pine needle matrix. A fat to fat-retainer ratio of 0.0057 (corresponding to 35 g of Florisil per 10 g of pine needle sample) was selected to minimise the co-elution of matrix-interfering compounds. Three 5-min extractions were performed using 25:75 (v/v) dichloromethane:n-hexane and a solvent flush of 150%. The mean recovery of spiked current-use pesticides, historic-use pesticides and PCBs using this method was 71%, 72%, and 84%, respectively. The method was validated by comparing target analyte concentrations measured in a pine needle sample using the optimised S-PLE method to those obtained using a conventional PLE method with external clean-up. The method detection limits and reproducibility were similar for the two methods; however, sample preparation time was 67% shorter when using the S-PLE method"
Keywords:Hexanes/chemistry Limit of Detection Lipids/chemistry Liquid-Liquid Extraction/*methods Pesticides/analysis/*isolation & purification Pinus/*chemistry Plant Leaves/chemistry Polychlorinated Biphenyls/analysis/*isolation & purification Pressure Reproducibi;
Notes:"MedlineLavin, Karen S Hageman, Kimberly J eng Research Support, Non-U.S. Gov't Netherlands 2012/09/04 J Chromatogr A. 2012 Oct 5; 1258:30-6. doi: 10.1016/j.chroma.2012.08.042. Epub 2012 Aug 17"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024