Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAldehyde perception induces specific molecular responses in Laminaria digitata and affects algal consumption by a specialist grazer    Next AbstractAntifungal Activity of Volatile Components from Ceratocystis fimbriata and Its Potential Biocontrol Mechanism on Alternaria alternata in Postharvest Cherry Tomato Fruit »

Nanoscale


Title:Au-modified three-dimensional In(2)O(3) inverse opals: synthesis and improved performance for acetone sensing toward diagnosis of diabetes
Author(s):Xing R; Li Q; Xia L; Song J; Xu L; Zhang J; Xie Y; Song H;
Address:"State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China. linxu@jlu.edu.cn songhw@jlu.edu.cn"
Journal Title:Nanoscale
Year:2015
Volume:7
Issue:30
Page Number:13051 - 13060
DOI: 10.1039/c5nr02709h
ISSN/ISBN:2040-3372 (Electronic) 2040-3364 (Linking)
Abstract:"Analyzing the volatile organic compounds (VOCs) in exhaled breath effectively is crucial to medical treatment, which can provide a fast and noninvasive way to diagnose disease. Well-designed materials with controlled structures have great influence on the sensing performance. In this work, the ordered three dimensional inverse opal (3DIO) macroporous In2O3 films with additional via-hole architectures were fabricated and different amounts of gold nanoparticles (Au NPs) were loaded on the In2O3 films aiming at enhancing their electrical responses. The gas sensing to acetone toward diabetes diagnosis in exhaled breath was performed with different Au/In2O3 electrodes. Representatively, the best 3DIO Au/In2O3 sensor can detect acetone effectively at 340 degrees C with response of 42.4 to 5 ppm, the actual detection limit is as low as 20 ppb, and it holds a dynamic response of 11 s and a good selectivity. Moreover, clinical tests proved that the as-prepared 3DIO Au/In2O3 IO sensor could distinguish acetone biomarkers in human breath clearly. The excellent gas sensing properties of the Au/In2O3 electrodes were attributed to the 'spillover effects' between Au and In2O3 and the special 3DIO structure. This work indicates that 3DIO Au/In2O3 composite is a promising electrode material for actual application in the monitoring and detection of diabetes through exhaled breath"
Keywords:Acetone/*analysis/chemistry Biosensing Techniques Breath Tests/instrumentation/*methods Diabetes Mellitus/diagnosis *Electrochemical Techniques Electrodes Gold/chemistry Humans Indium/*chemistry Limit of Detection Metal Nanoparticles/chemistry Nanostructu;
Notes:"MedlineXing, Ruiqing Li, Qingling Xia, Lei Song, Jian Xu, Lin Zhang, Jiahuan Xie, Yi Song, Hongwei eng Research Support, Non-U.S. Gov't England 2015/07/15 Nanoscale. 2015 Aug 14; 7(30):13051-60. doi: 10.1039/c5nr02709h"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024