Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAdsorption of trichloroethylene on common indoor materials studied using a combined inverse gas chromatography and frequency response technique    Next AbstractEnantioseparations by Gas Chromatography Using Porous Organic Cages as Stationary Phase »

J Hazard Mater


Title:Contaminant sorption on soil and indoor materials and its possible impact on transients in vapor intrusion- An example based upon trichloroethylene (TCE)
Author(s):Xie S; Strom JGV; Suuberg EM;
Address:"Brown University, School of Engineering, Providence, RI, USA"
Journal Title:J Hazard Mater
Year:2023
Volume:20230104
Issue:
Page Number: -
DOI: 10.1016/j.jhazmat.2023.130721
ISSN/ISBN:1873-3336 (Electronic) 0304-3894 (Print) 0304-3894 (Linking)
Abstract:"Although building materials are well recognized as potential sources and sinks of indoor volatile organic compounds (VOCs), knowledge about how they affect indoor air concentrations and measurements in vapor intrusion scenarios is limited. This study investigates the potential influence of sorption processes on indoor air contamination in vapor intrusion, relying upon laboratory measurements at relevant concentration levels, and applying these in a numerical transient vapor intrusion model. It was found that the sink effect of adsorption on building materials can lower indoor air concentrations or delay their achieving a steady state, thus cautioning that these processes can affect observed indoor air concentration variability. Building materials can also serve as secondary sources of pollutants in vapor intrusion mitigation scenarios, which might affect the evaluation of the efficiency of mitigation efforts. For example, it was predicted that in a cinderblock structure it could take up to 305 hours to reduce indoor trichloroethylene (TCE) concentrations by 50% due to the re-emission of TCE from the cinderblock, whereas it would take only 1.4 hours without the re-emission process"
Keywords:Building Materials Mitigation Sorption Process Temporal Variability Vapor Intrusion;
Notes:"PubMed-not-MEDLINEXie, Shuai Strom, Jonathan G V Suuberg, Eric M eng P42 ES013660/ES/NIEHS NIH HHS/ Netherlands 2023/05/04 J Hazard Mater. 2023 Mar 15; 446:130721. doi: 10.1016/j.jhazmat.2023.130721. Epub 2023 Jan 4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024