Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEvaluation of emissions and exposures at workplaces using desktop 3-dimensional printer    Next Abstract"Additive Manufacturing for Occupational Hygiene: A Comprehensive Review of Processes, Emissions, & Exposures" »

Saf Health Work


Title:Insights Into Emissions and Exposures From Use of Industrial-Scale Additive Manufacturing Machines
Author(s):Stefaniak AB; Johnson AR; Du Preez S; Hammond DR; Wells JR; Ham JE; LeBouf RF; Martin SB; Duling MG; Bowers LN; Knepp AK; de Beer DJ; Du Plessis JL;
Address:"National Institute for Occupational Safety and Health, Morgantown, WV, 26505, USA. North-West University, Occupational Hygiene and Health Research Initiative, Private Bag X6001, Potchefstroom, 2520, South Africa. National Institute for Occupational Safety and Health, Cincinnati, OH, 45213, USA. North-West University, Technology and Innovation Support Office, Private Bag X6001, Potchefstroom, 2520, South Africa"
Journal Title:Saf Health Work
Year:2019
Volume:20181109
Issue:2
Page Number:229 - 236
DOI: 10.1016/j.shaw.2018.10.003
ISSN/ISBN:2093-7911 (Print) 2093-7997 (Electronic) 2093-7911 (Linking)
Abstract:"BACKGROUND: Emerging reports suggest the potential for adverse health effects from exposure to emissions from some additive manufacturing (AM) processes. There is a paucity of real-world data on emissions from AM machines in industrial workplaces and personal exposures among AM operators. METHODS: Airborne particle and organic chemical emissions and personal exposures were characterized using real-time and time-integrated sampling techniques in four manufacturing facilities using industrial-scale material extrusion and material jetting AM processes. RESULTS: Using a condensation nuclei counter, number-based particle emission rates (ERs) (number/min) from material extrusion AM machines ranged from 4.1 x 10(10) (Ultem filament) to 2.2 x 10(11) [acrylonitrile butadiene styrene and polycarbonate filaments). For these same machines, total volatile organic compound ERs (mug/min) ranged from 1.9 x 10(4) (acrylonitrile butadiene styrene and polycarbonate) to 9.4 x 10(4) (Ultem). For the material jetting machines, the number-based particle ER was higher when the lid was open (2.3 x 10(10) number/min) than when the lid was closed (1.5-5.5 x 10(9) number/min); total volatile organic compound ERs were similar regardless of the lid position. Low levels of acetone, benzene, toluene, and m,p-xylene were common to both AM processes. Carbonyl compounds were detected; however, none were specifically attributed to the AM processes. Personal exposures to metals (aluminum and iron) and eight volatile organic compounds were all below National Institute for Occupational Safety and Health (NIOSH)-recommended exposure levels. CONCLUSION: Industrial-scale AM machines using thermoplastics and resins released particles and organic vapors into workplace air. More research is needed to understand factors influencing real-world industrial-scale AM process emissions and exposures"
Keywords:Additive manufacturing Material extrusion Material jetting Ultrafine particles Volatile organic compounds;
Notes:"PubMed-not-MEDLINEStefaniak, A B Johnson, A R du Preez, S Hammond, D R Wells, J R Ham, J E LeBouf, R F Martin, S B Jr Duling, M G Bowers, L N Knepp, A K de Beer, D J du Plessis, J L eng Korea (South) 2019/07/13 Saf Health Work. 2019 Jun; 10(2):229-236. doi: 10.1016/j.shaw.2018.10.003. Epub 2018 Nov 9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-11-2024