Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMeasurement of emotional states of zebrafish through integrated analysis of motion and respiration using bioelectric signals    Next AbstractEquilibria of semi-volatile isothiazolinones between air and glass surfaces measured by gas chromatography and Raman spectroscopy »

J Environ Manage


Title:Indoor air quality investigation according to age of the school buildings in Korea
Author(s):Sohn J; Yang W; Kim J; Son B; Park J;
Address:"Department of Occupational Health, Catholic University of Daegu, Hayang-eup, Gyeongsan-si, Kyongbuk 712-702, South Korea. whyang@cu.ac.kr"
Journal Title:J Environ Manage
Year:2009
Volume:20080220
Issue:1
Page Number:348 - 354
DOI: 10.1016/j.jenvman.2007.10.003
ISSN/ISBN:0301-4797 (Print) 0301-4797 (Linking)
Abstract:"Since the majority of schools are housed in buildings dating from the 1960s and 1970s, a comprehensive construction and renovation program of school buildings has been carried out to improve the educational conditions in Korea. However, classrooms and computer rooms, with pressed wood desks, chairs and furnishings, as well as construction materials, might have negative effects on the indoor air quality. Furthermore, most schools have naturally ventilated classrooms. The purpose of this study was to characterize the concentrations of different indoor air pollutants within Korean schools and to compare their indoor levels within schools according to the age of school buildings. Indoor and outdoor air samples of carbon monoxide (CO), carbon dioxide (CO(2)), particulate matter (PM(10)), total microbial count (TBC), total volatile organic compounds (TVOCs) and formaldehyde (HCHO) were obtained during summer, autumn and winter from three sites; a classroom, a laboratory and a computer classroom at 55 different schools. The selection of the schools was based on the number of years since the schools had been constructed. The problems causing indoor air pollution at the schools were chemicals emitted by building materials or furnishings, and insufficient ventilation rates. The I/O ratio for HCHO was 6.32 during the autumn, and the indoor HCHO concentrations (mean = 0.16 ppm) in schools constructed within 1 year were significantly higher than the Korean Indoor Air Standard, indicating that schools have indoor sources of HCHO. Therefore, increasing the ventilation rate by means of a mechanical system and the use of low-emission furnishings can play key roles in improving the indoor air quality within schools"
Keywords:"Adolescent Air/*analysis Air Microbiology Air Pollution Air Pollution, Indoor/*analysis Bacteria/isolation & purification Child Child, Preschool Computers Facility Design and Construction/*standards Humans Humidity Korea *Schools Seasons Temperature;"
Notes:"MedlineSohn, Jongryeul Yang, Wonho Kim, Jihwan Son, Busoon Park, Jinchul eng Research Support, Non-U.S. Gov't England 2007/12/15 J Environ Manage. 2009 Jan; 90(1):348-54. doi: 10.1016/j.jenvman.2007.10.003. Epub 2008 Feb 20"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024