Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAn integrative 'omics' approach identifies new candidate genes to impact aroma volatiles in peach fruit    Next Abstract"Development of a multibed sorption trap, comprehensive two-dimensional gas chromatography, and time-of-flight mass spectrometry system for the analysis of volatile organic compounds in human breath" »

Anal Chem


Title:GC analysis of human breath with a series-coupled column ensemble and a multibed sorption trap
Author(s):Sanchez JM; Sacks RD;
Address:"Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA"
Journal Title:Anal Chem
Year:2003
Volume:75
Issue:10
Page Number:2231 - 2236
DOI: 10.1021/ac020725g
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"The combination of a tandem column ensemble and an on-line microsorption trap is used for the analysis of organic compounds in human breath samples. The four-bed sorption trap uses a series of discreet sorption beds containing three grades of graphitized carbon and a carbon molecular sieve to quantitatively remove most organic compounds from 0.8-L breath samples. The trap is then heated to 300 degrees C in approximately 1.5 s and maintained at this temperature for 10 s. The resulting vapor plug width is in the range 0.7-1.3 s for the compounds found in the breath samples. The separation is performed with a 15-m-long, 0.25-mm-i.d. capillary using a 0.5-microm-thick film of nonpolar dimethyl polysiloxane coupled in series to a polar column, either trifluoropropylmethyl polysiloxane or poly(ethylene glycol). Both column combinations are successful in separating the early-eluting compounds acetone, isoprene, pentane, methyl alcohol, and ethyl alcohol, which are all common in breath samples. The poly(ethylene glycol) combination gave better separation but showed relatively fast deterioration for repeated analysis of wet samples. Breath samples were obtained under different conditions (smoker, nonsmoker, gum chewer), and 25 compounds were identified in the various samples. Many additional peaks are observed but not identified. Analytical curves (log-log) of peak area versus sample volume for test compounds are linear in the range 80-800 cm3. Detection limits (3sigma) for several volatile compounds in 800-cm3 samples are in the 1-5 ppb range"
Keywords:"Adsorption Breath Tests/*instrumentation/methods Chromatography, Gas/*instrumentation/methods Humans Organic Chemicals/analysis Volatilization;"
Notes:"MedlineSanchez, Juan M Sacks, Richard D eng R01-OH03692/OH/NIOSH CDC HHS/ Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. Research Support, U.S. Gov't, P.H.S. 2003/08/16 Anal Chem. 2003 May 15; 75(10):2231-6. doi: 10.1021/ac020725g"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024