Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBed bug dermatitis: detection dog as a useful survey tool for environmental research of Cimex lectularius    Next AbstractAnalysis of the acidic fraction of marijuana smoke condensate by capillary gas chromatography-mass spectrometry »

Aerosol Air Qual Res


Title:Evaluation and Field Calibration of a Low-Cost Ozone Monitor at a Regulatory Urban Monitoring Station
Author(s):Masiol M; Squizzato S; Chalupa D; Rich DQ; Hopke PK;
Address:"Department of Public Health Sciences, University of Rochester Medical Center, Rochester, NY 14642. Department of Environmental Medicine, University of Rochester Medical Center, Rochester, NY 14642, United States. Center for Air Resources Engineering and Science, Clarkson University, Potsdam, NY 13699"
Journal Title:Aerosol Air Qual Res
Year:2018
Volume:20180727
Issue:8
Page Number:2029 - 2037
DOI: 10.4209/aaqr.2018.02.0056
ISSN/ISBN:1680-8584 (Print) 2071-1409 (Electronic) 1680-8584 (Linking)
Abstract:"The performance of a low cost ozone monitor (Aeroqual Series 500 portable gas monitors using a metal oxide sensor for ozone; model OZL) was assessed under field conditions. Ten ozone monitors were calibrated under clean-air laboratory conditions and controlled ozone concentrations of 5 to 100 ppb. Good linearity and response were obtained relative to a research-grade ozone monitor. One monitor was co-located at a regulatory air quality monitoring station that uses a U.S. federal equivalent method (FEM) ozone analyzer. Raw data from the Aeroqual monitor collected over 4 months (June-October) at a 10-minute time-resolution, showed good agreement (r(2)=0.83) with the FEM values but with an overestimation of ~12%. Data were averaged to different time resolutions; 1 h time averaged concentrations showed the best fit with the FEM results (r(2)=0.87). Data analyses suggested the potential of interferences due to temperature, relative humidity, nitrogen oxides, and volatile organic compounds. Correction models using temperature, humidity, and nitrogen dioxide (NO(2)) were tested to relate the monitor concentrations to the FEM values. Temperature and humidity were two readily available variables. The model (#3) that added NO(2) did not provide a substantial improvement in the fit. Thus, the models with only temperature and humidity can be easily developed by any user. The best model explained 91% of the variance and showed statistically significant improvement of the goodness of fits as well as decreased influence of the interfering variables on the diurnal and weekly patterns. The correction models were also able to lower the effect of seasonal temperature changes, allowing the use of the monitors over long-term sampling campaigns. Thus, the Aeroqual ozone monitor can return 'FEM-like' concentrations after appropriate corrections. Data provided by a network of monitors could provide intra-urban spatial variations in ozone concentrations and provide more accurate human exposure assessments by reducing exposure misclassification"
Keywords:Semiconductor gas sensor air pollution exposure tropospheric ozone urban air pollution;
Notes:"PubMed-not-MEDLINEMasiol, Mauro Squizzato, Stefania Chalupa, David Rich, David Q Hopke, Philip K eng P30 ES001247/ES/NIEHS NIH HHS/ China (Republic : 1949- ) 2018/08/01 Aerosol Air Qual Res. 2018 Aug; 18(8):2029-2037. doi: 10.4209/aaqr.2018.02.0056. Epub 2018 Jul 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-11-2024