Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMonitorization of Varietal Aroma Composition Dynamics during Ripening in Intact Vitis vinifera L. Tempranillo Blanco Berries by Hyperspectral Imaging    Next AbstractMetabolic Fingerprinting of Muscat of Alexandria Grape Musts during Industrial Alcoholic Fermentation Using HS-SPME and Liquid Injection with TMS Derivatization GC-MS Methods »

J Occup Environ Hyg


Title:A new approach for diffusive sampling based on SPME for occupational exposure assessment
Author(s):Marin P; Periago JF; Prado C;
Address:"Departamento de Ciencias Sociosanitarias, Universidad de Murcia, Facultad de Medicina, Murcia, Spain"
Journal Title:J Occup Environ Hyg
Year:2013
Volume:10
Issue:3
Page Number:132 - 142
DOI: 10.1080/15459624.2012.755091
ISSN/ISBN:1545-9632 (Electronic) 1545-9624 (Linking)
Abstract:"Passive sampling is a well-established methodology for the evaluation of exposures to environmental volatile organic compounds (VOCs). The solid-phase microextraction (SPME) technique is a reliable means of sampling VOCs in air. SPME is also being applied as a passive sampler to determine time-weighted average exposure. The use of SPME as a diffusive sampler was evaluated. The passive sampler is based on the use of a cylindrical diffusion cell (porous hydrophobic polyethylene) with an 80 mum carboxen/polydimethylsiloxane fiber to obtain radial diffusion of the analytes to the sorbent. Standard atmospheres of organic vapors in air were used to determine the experimental uptake rates for toluene and chlorobenzene. Toluene concentrations between 2 and 38 mg/m(3) with sampling times between 15 and 60 min were evaluated, as well as chlorobenzene concentrations between 2 and 47 mg/m(3) with sampling times between 30 and 60 min. The mean diffusive uptake rate was 2.14 mL/min for toluene and 2.57 mL/min for chlorobenzene, and no statistical significant effects of concentration and sampling time were observed under the studied conditions for the two compounds. Relative standard deviation ranged from 2.6 to 6.5%. The performance of the sampler under varying concentrations of toluene was also tested, showing that the sampler reflects the average exposure concentration. Effects of temperature, relative humidity, velocity of the air, back diffusion, competitive adsorption, and the stability of chlorobenzene in the sampler were also studied. Sampler behavior was tested in gas stations, and the results were successfully compared with a 3M-3500 diffusive sampler. The results are promising for using this new SPME device for diffusive monitoring for occupational exposure assessment"
Keywords:"Air Pollutants, Occupational/analysis Chlorobenzenes/*analysis Chromatography, Gas Diffusion Environmental Monitoring/*methods Humidity Occupational Exposure/*analysis *Solid Phase Microextraction Temperature Toluene/*analysis Volatile Organic Compounds/a;"
Notes:"MedlineMarin, P Periago, J F Prado, C eng England 2013/01/30 J Occup Environ Hyg. 2013; 10(3):132-42. doi: 10.1080/15459624.2012.755091"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024