Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractA Drosophila DEG/ENaC channel subunit is required for male response to female pheromones    Next Abstract"Highly efficient and mild electrochemical mineralization of long-chain perfluorocarboxylic acids (C9-C10) by Ti/SnO2-Sb-Ce, Ti/SnO2-Sb/Ce-PbO2, and Ti/BDD electrodes" »

J Am Chem Soc


Title:A colorimetric sensor array for detection of triacetone triperoxide vapor
Author(s):Lin H; Suslick KS;
Address:"Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, USA"
Journal Title:J Am Chem Soc
Year:2010
Volume:132
Issue:44
Page Number:15519 - 15521
DOI: 10.1021/ja107419t
ISSN/ISBN:1520-5126 (Electronic) 0002-7863 (Linking)
Abstract:"Triacetone triperoxide (TATP), one of the most dangerous primary explosives, has emerged as an explosive of choice for terrorists in recent years. Owing to the lack of UV absorbance, fluorescence, or facile ionization, TATP is extremely difficult to detect directly. Techniques that are able to detect generally require expensive instrumentation, need extensive sample preparation, or cannot detect TATP in the gas phase. Here we report a simple and highly sensitive colorimetric sensor for the detection of TATP vapor with semiquantitative analysis from 50 ppb to 10 ppm. By using a solid acid catalyst to pretreat a gas stream, we have discovered that a colorimetric sensor array of redox sensitive dyes can detect even very low levels of TATP vapor from its acid decomposition products (e.g., H(2)O(2)) with limits of detection (LOD) below 2 ppb (i.e., <0.02% of its saturation vapor pressure). Common potential interferences (e.g., humidity, personal hygiene products, perfume, laundry supplies, volatile organic compounds, etc.) do not generate an array response, and the array can also differentiate TATP from other chemical oxidants (e.g., hydrogen peroxide, bleach, tert-butylhydroperoxide, peracetic acid)"
Keywords:"Colorimetry/*methods Coloring Agents/*chemistry Heterocyclic Compounds, 1-Ring/*chemistry Limit of Detection Molecular Structure Peroxides/*chemistry Volatilization;"
Notes:"MedlineLin, Hengwei Suslick, Kenneth S eng U01ES016011/ES/NIEHS NIH HHS/ Research Support, N.I.H., Extramural 2010/10/19 J Am Chem Soc. 2010 Nov 10; 132(44):15519-21. doi: 10.1021/ja107419t"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024