J Hazard Mater


Title:Accelerated solvent extraction (ASE) of environmental organic compounds in soils using a modified supercritical fluid extractor
Author(s):Li K; Landriault M; Fingas M; Llompart M;
Address:"Emergencies Science Division, Environment Canada, Environmental Technology Centre, River Road, Ottawa, Ont, Canada K1A OH3. li.ken@etc.ec.gc.ca"
Journal Title:J Hazard Mater
Year:2003
Volume:102
Issue:1
Page Number:93 - 104
DOI: 10.1016/s0304-3894(03)00204-8
ISSN/ISBN:0304-3894 (Print) 0304-3894 (Linking)
Abstract:"Accelerated solvent extraction (ASE) has been applied to the quantitative extraction of a selected list of semi-volatiles, which include polycyclic aromatic hydrocarbons (PAHs), phenols, polychlorinated biphenyls (PCBs) and total petroleum hydrocarbons. Two conventional supercritical fluid extraction (SFE) systems, the Suprex Prep Master and SFE/50 systems have been modified to function as ASE systems. Using solvent instead of supercritical fluid, extraction in an enclosed system proceeded under high pressure and temperature. Parameters such as extraction temperature and effect of modifiers were investigated. Although limited by a 150 degrees C maximum oven temperature, effective extraction could be carried out in less than 25 min for all the compounds studied. The technique was applied to a variety of real matrices contaminated with hydrocarbons, PAHs and phenols. Validations of the technique were performed using standard reference materials. Recoveries for these matrices were good (>75%) and precision (R.S.D.) was generally less than 10%. Primarily a rapid field extraction technique, comparison with other rapid extraction such as sonication and microwave assisted extraction (MAP) were made. Recoveries were found to be comparable to MAP and superior to sonication. On the present ASE system, only sequential extraction can be carried out but given the rapid nature of the process, about 15 samples can be carried out in a working day"
Keywords:"Chemistry Techniques, Analytical/methods Environmental Monitoring/*methods Environmental Pollutants/*analysis Petroleum/*analysis Phenols/*analysis Polychlorinated Biphenyls/*analysis Polycyclic Aromatic Hydrocarbons/*analysis Reference Values Reproducibi;"
Notes:"MedlineLi, Ken Landriault, Michael Fingas, Merv Llompart, Maria eng Evaluation Study Research Support, Non-U.S. Gov't Netherlands 2003/09/10 J Hazard Mater. 2003 Aug 15; 102(1):93-104. doi: 10.1016/s0304-3894(03)00204-8"

 