Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEmissions of Fungal Volatile Organic Compounds in Residential Environments and Temporal Emission Patterns: Implications for Sampling Methods    Next AbstractEffects of injection volume change on gas chromatographic sensitivity determined with two contrasting calibration approaches for volatile organic compounds »

Talanta


Title:Comparative analysis of bias in the collection of airborne pollutants: Tests on major aromatic VOC using three types of sorbent-based methods
Author(s):Kim KH; Oh SI; Choi YJ;
Address:"Department of Earth & Environmental Sciences, Sejong University, Goon Ja Dong 98, Seoul 143-747, South Korea"
Journal Title:Talanta
Year:2004
Volume:64
Issue:2
Page Number:518 - 527
DOI: 10.1016/j.talanta.2004.03.019
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"This study was undertaken to establish one of the most reliable sampling methods and to precisely evaluate the bias involved in the collection of airborne pollutant samples. For the purpose of our study, we investigated the performance of three different types of sampling techniques by measuring major aromatic volatile organic compounds (VOC) in outdoor air; the target analytes specifically include benzene, toluene, ethylbenzene, and xylene (commonly called BTEX). As the first step of our approach, we designed and developed a multi-channel sampling system consisting of a six-port mass flow controller (SJU-MFC) system. Because this system allowed the collection of up to six replicate samples, our measurement results were analyzed and screened statistically for the derivation of high-quality BTEX data. The feasibility of this sampling system was further tested through a comparison with concurrent measurement data sets obtained by two additional, but independent, sampling techniques: (1) automatic continuous sampler (ACS) and (2) on-line GC (O-GC) system. Based on the data sets collected concurrently by three different sampling methods, we attempted to evaluate the compatibility of sampling techniques. Although the results obtained by SJU-MFC system were not statistically different from those of the O-GC system, they were moderately distinguishable from those of ACS. Such patterns were seen consistently, when examined by correlation analysis. The overall results of our study thus generally point out that the compatibility of data sets, when the proper caution is taken, improve significantly among different sampling methodologies"
Keywords:
Notes:"PubMed-not-MEDLINEKim, Ki-Hyun Oh, Sang-In Choi, Ye-Jin eng Netherlands 2008/10/31 Talanta. 2004 Oct 8; 64(2):518-27. doi: 10.1016/j.talanta.2004.03.019"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 03-07-2024