« Previous AbstractMethyl jasmonate does not induce changes in Eucalyptus grandis leaves that alter the effect of constitutive defences on larvae of a specialist herbivore    Next Abstract"Beta1,3-N-acetylglucosaminyltransferase 1 glycosylation is required for axon pathfinding by olfactory sensory neurons" »

Anal Chem


Title:Gas Analysis by Electron Ionization Combined with Chemical Ionization in a Compact FTICR Mass Spectrometer
Author(s):Heninger M; Mestdagh H; Louarn E; Mauclaire G; Boissel P; Leprovost J; Bauchard E; Thomas S; Lemaire J;
Address:"Laboratoire de Chimie Physique, CNRS, Univ. Paris-Sud, Universite Paris-Saclay , 91405 Orsay , France. AlyXan , Centre Hoche, 3 rue Condorcet , 91260 Juvisy sur Orge , France"
Journal Title:Anal Chem
Year:2018
Volume:20180531
Issue:12
Page Number:7517 - 7525
DOI: 10.1021/acs.analchem.8b01107
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"In this Article, a compact Fourier transform ion cyclotron resonance (FTICR) mass spectrometer based on a permanent magnet is presented. This instrument has been developed for real-time analysis of gas emissions. The instrument is well-suited to industrial applications or analysis of toxic and complex samples where the concentrations can vary rapidly on a wide range. The novelty of this instrument is the ability to use either electron ionization (EI) or chemical ionization (CI) individually or both of them alternatively. Also in CI mode, different precursor ions can be used alternatively. Volatile organic compounds (VOCs) from the ppb level to very high concentrations (% level) can be detected by CI or EI. The magnet is composed of three Halbach arrays, and the nominal field achieved is 1.5 T. The ICR cell is a 3 cm side length cubic cell. The mass range is 12-200 u with a broad band detection. The mass accuracy of 0.005 u and the resolving power allow the separation of isobaric ions such as C(3)H(8)(+) and CO(2)(+). Gas introduction via controlled gas pulses, electron ionization, ion-molecule reactions, ion selection, and detection are all performed in the ICR cell. The potential of the instrument will be illustrated by an analysis of a gas mixture containing trace components at ppm level (VOCs) and components in the 0.5-100% range (N(2), alkanes, and CO(2))"
Keywords:
Notes:"PubMed-not-MEDLINEHeninger, Michel Mestdagh, Helene Louarn, Essyllt Mauclaire, Gerard Boissel, Pierre Leprovost, Julien Bauchard, Elsa Thomas, Sebastien Lemaire, Joel eng 2018/05/22 Anal Chem. 2018 Jun 19; 90(12):7517-7525. doi: 10.1021/acs.analchem.8b01107. Epub 2018 May 31"

 