Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGregarious settlement in cypris larvae:the effects of cyprid age and assay duration    Next AbstractModeling MTBE and BTEX in lakes and reservoirs used for recreational boating »

Ultramicroscopy


Title:Enhancing chemi-mechanical transduction in microcantilever chemical sensing by surface modification
Author(s):Headrick JJ; Sepaniak MJ; Lavrik NV; Datskos PG;
Address:"Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA"
Journal Title:Ultramicroscopy
Year:2003
Volume:97
Issue:1-Apr
Page Number:417 - 424
DOI: 10.1016/S0304-3991(03)00069-X
ISSN/ISBN:0304-3991 (Print) 0304-3991 (Linking)
Abstract:"The use of chemically selective thin-film coatings has been shown to enhance both the chemical selectivity and sensitivity of microcantilever (MC) chemical sensors. As an analyte absorbs into the coating, the coating can swell or contract causing an in-plane stress at the associated MC surface. However, much of the stress upon absorption of an analyte may be lost through slippage of the chemical coatings on the MC surface, or through relaxation of the coating in a manner that minimizes stress to the cantilever. Structural modification of MC chemical sensors can improve the stress transduction between the chemical coating and the MC. Surfaces of silicon MC were modified with focused ion beam milling. Sub-micron channels were milled across the width of the MC. Responses of the nanostructured, coated MCs to 2,3-dihydroxynaphthalene and a series of volatile organic compounds (VOCs) were compared to smooth, coated MCs. The analytical figures of merit for the nanostructured, coated MCs in the sensing of VOCs were found to be better than the unstructured MCs. A comparison is made with a previously reported method of creating disordered nanostructured MC surfaces"
Keywords:
Notes:"PubMed-not-MEDLINEHeadrick, J J Sepaniak, M J Lavrik, N V Datskos, P G eng Netherlands 2003/06/13 Ultramicroscopy. 2003 Oct-Nov; 97(1-4):417-24. doi: 10.1016/S0304-3991(03)00069-X"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024