Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDetermining indoor air quality and identifying the origin of odour episodes in indoor environments    Next Abstract"Comparative study of the adsorption performance of an active multi-sorbent bed tube (Carbotrap, Carbopack X, Carboxen 569) and a Radiello((R)) diffusive sampler for the analysis of VOCs" »

Talanta


Title:"Comparative study of the adsorption performance of a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and a Tenax TA adsorbent tube for the analysis of volatile organic compounds (VOCs)"
Author(s):Gallego E; Roca FJ; Perales JF; Guardino X;
Address:"Laboratori del Centre de Medi Ambient, Universitat Politecnica de Catalunya (LCMA-UPC), Avda. Diagonal, Barcelona, Spain. Lcma.info@upc.edu"
Journal Title:Talanta
Year:2010
Volume:20100125
Issue:3
Page Number:916 - 924
DOI: 10.1016/j.talanta.2010.01.037
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"A comparison between two types of adsorbent tubes, the commonly used Tenax TA and a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) tube developed in our laboratory, has been done to evaluate their usefulness in the analysis of VOCs in ambient air. Duplicate indoor and outdoor samples of Tenax TA and multi-sorbent tubes of 10, 20, 40, 60 and 90l were taken in Barcelona city (Spain) on July and October of 2009. Breakthrough values (defined as %VOCs found in the back tube) were determined for all sampling volumes connecting two sampling tubes in series. The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detector (MSD). Significant differences between the concentrations obtained-from multi-sorbent bed and Tenax TA tubes are observed for the very volatile compounds (56 degrees C
Keywords:"Adsorption Air Pollutants/analysis Air Pollution Air Pollution, Indoor/analysis Automation Bicyclic Monoterpenes Carbon/*chemistry *Chemistry Techniques, Analytical Environmental Monitoring Monoterpenes/analysis Polymers/*chemistry Pressure Temperature Vo;"
Notes:"MedlineGallego, E Roca, F J Perales, J F Guardino, X eng Netherlands 2010/03/20 Talanta. 2010 May 15; 81(3):916-24. doi: 10.1016/j.talanta.2010.01.037. Epub 2010 Jan 25"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024