|
Surg Endosc
Title: | Activated carbon fiber filters could reduce the risk of surgical smoke exposure during laparoscopic surgery: application of volatile organic compounds |
|
Author(s): | Choi SH; Choi DH; Kang DH; Ha YS; Lee JN; Kim BS; Kim HT; Yoo ES; Kwon TG; Chung SK; Kim TH; |
|
Address: | "Department of Urology, School of Medicine, Kyungpook National University, Daegu, Republic of Korea. Department of Urology, Kyungpook National University Hospital, Daegu, Republic of Korea. Department of Architectural Engineering, Kyungil University, Gyeongsan, Republic of Korea. Department of Architectural Engineering, University of Seoul, Seoul, Republic of Korea. Department of Urology, Kyungpook National University Medical Center, 807 Hoguk-ro, Buk-gu, Daegu, 41404, Republic of Korea. Department of Urology, School of Medicine, Kyungpook National University, Daegu, Republic of Korea. doctork@knu.ac.kr. Department of Urology, Kyungpook National University Medical Center, 807 Hoguk-ro, Buk-gu, Daegu, 41404, Republic of Korea. doctork@knu.ac.kr" |
|
Journal Title: | Surg Endosc |
Year: | 2018 |
Volume: | 20180516 |
Issue: | 10 |
Page Number: | 4290 - 4298 |
DOI: | 10.1007/s00464-018-6222-0 |
|
ISSN/ISBN: | 1432-2218 (Electronic) 0930-2794 (Linking) |
|
Abstract: | "BACKGROUND: Generation of smoke is inevitable during surgical procedures. Some volatile organic compounds (VOCs) in surgical smoke are known to be strong carcinogens. We used a prototype of a multi-layered complex filter in an attempt to eliminate VOCs. METHODS: From June 2015 to July 2015, 20 patients underwent transperitoneal laparoscopic nephrectomy for renal cell carcinoma. Smoke (pre-filter) was collected 20 min after the electrocautery device was first used during the surgery, by the direct collection method, with a 5-L Tedlar(R) gas-sampling bag. Twenty and 120 min after the filter was applied, smoke (post-filter) was again collected using the same method. The sample was analyzed by gas chromatography and mass spectrography. The cancer risk and hazard quotient were analyzed based on US Environmental Protection Agency guidelines. RESULTS: Twenty patients with a median age of 54.5 (30-80) years were enrolled in the study. Eighteen VOCs were detected using the Japanese indoor air standards mix analysis. The total elimination rate of the VOCs was 86.49 +/- 2.83%. The post-filter (120 min) cancer risk (mean +/- standard deviation) reduced to a negligible level for benzene, ethylbenzene, and styrene except 1,2-dichloroethane. The post-filter (120 min) hazard quotient for each compound decreased to levels posing a negligible risk for acetone, hexane, benzene, toluene, p-xylene, o-xylene, and styrene. CONCLUSION: Strong carcinogens, such as 1,2-dichloroethane, benzene, and ethylbenzene, were eliminated by more than 85% by using this activated carbon fiber filter and the risks from these compounds decreased to an almost negligible level. We suggest using every measure, including these filters, to protect the health of operating room personnel" |
|
Keywords: | "Adult Aged Aged, 80 and over Air Pollutants, Occupational/*chemistry *Carbon Fiber *Carcinogens Electrocoagulation Filtration/*instrumentation Humans Laparoscopy/*adverse effects/instrumentation Middle Aged Occupational Exposure/analysis/*prevention & con;" |
|
Notes: | "MedlineChoi, Seock Hwan Choi, Dong Hee Kang, Dong Hwa Ha, Yun-Sok Lee, Jun Nyung Kim, Bum Soo Kim, Hyun Tae Yoo, Eun Sang Kwon, Tae Gyun Chung, Sung Kwang Kim, Tae-Hwan eng Research Support, Non-U.S. Gov't Germany 2018/05/18 Surg Endosc. 2018 Oct; 32(10):4290-4298. doi: 10.1007/s00464-018-6222-0. Epub 2018 May 16" |
|
|
|
|
|
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024
|