Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMechanisms of Resistance to Insect Herbivores in Isolated Breeding Lineages of Cucurbita pepo    Next Abstract[Implementation of a pretreatment device for an electronic nose] »

Huan Jing Ke Xue


Title:[Applicability of an electronic nose for detection of volatile chlorinated hydrocarbons in soil]
Author(s):Bu FY; Wen XG; Wan M; Liu R; Cai Q; Chen LJ; Zhang YM;
Address:"College of Life and Environmental Science, Shanghai Normal University, Shanghai 200234, China. bufanyang1986@163.com"
Journal Title:Huan Jing Ke Xue
Year:2011
Volume:32
Issue:12
Page Number:3641 - 3646
DOI:
ISSN/ISBN:0250-3301 (Print) 0250-3301 (Linking)
Abstract:"An electronic nose principally composed of a photo ionization detector (PID) was developed for rapid detection of volatile chlorinated hydrocarbons (VCHs) in contaminated soil. Removal of interference gas such as benzene homologues with a pre-filtration tube was analyzed with gas chromatography (GC). A standard gas generator was applied to generate different concentrations of perchloroethylene (PCE) and trichloroethylene (TCE) gas, with which the determine precision and reproducibility of the electronic nose were evaluated by comparison with GC. Finally, simulated contamination soil with three typical paddy soils in Yangtze river delta region were used for ventilation purification experiments, the change of VCHs concentrations in the ventilation gas was monitored, based on which the applicability of the electronic nose was evaluated for on-line detection of the on-going of the ventilation purification process. Results showed that a halogenated hydrocarbon RAE-SEP tube was effective to remove interference gas, with 80%-97% of benzene homologues such as benzene and ethyl benzene being removed while more than 90% of VCHs passed through. With PCE or TCE gas, a linear dependence was derived between the data determined with the electronic nose and GC, the linear slope being 1.012 and R2 > 0.99. The electronic nose showed data consistent with GC (R2 > 0.99, n = 47) when applied for monitoring the remediation progress in a soil ventilation process. The electronic nose is therefore possibly applicable for rapid determination of soil pollution by VCHs, improving the efficiency of pollution diagnosis and remediation"
Keywords:"*Electronic Nose Environmental Monitoring/*methods Equipment Design Hydrocarbons, Chlorinated/*analysis Soil/analysis Soil Pollutants/*analysis Tetrachloroethylene/analysis Trichloroethylene/analysis Volatile Organic Compounds/analysis;"
Notes:"MedlineBu, Fan-Yang Wen, Xiao-Gang Wan, Mei Liu, Rui Cai, Qiang Chen, Lu-Jun Zhang, Yong-Ming chi Research Support, Non-U.S. Gov't China 2012/04/04 Huan Jing Ke Xue. 2011 Dec; 32(12):3641-6"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024