Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEddy covariance VOC emission and deposition fluxes above grassland using PTR-TOF    Next AbstractDevelopment of a stir bar sorptive extraction method to study different beer styles volatile profiles »

Anal Bioanal Chem


Title:A novel particle sampling system for physico-chemical and toxicological characterization of emissions
Author(s):Ruusunen J; Tapanainen M; Sippula O; Jalava PI; Lamberg H; Nuutinen K; Tissari J; Ihalainen M; Kuuspalo K; Maki-Paakkanen J; Hakulinen P; Pennanen A; Teinila K; Makkonen U; Salonen RO; Hillamo R; Hirvonen MR; Jokiniemi J;
Address:"Department of Environmental Science, University of Eastern Finland, Kuopio, Finland. jarno.ruusunen@uef.fi"
Journal Title:Anal Bioanal Chem
Year:2011
Volume:20110930
Issue:10
Page Number:3183 - 3195
DOI: 10.1007/s00216-011-5424-2
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"Several studies have shown that combustion-derived fine particles cause adverse health effects. Previous toxicological studies on combustion-derived fine particles have rarely involved multiple endpoints and a detailed characterization of chemical composition. In this study, we developed a novel particle sampling system for toxicological and chemical characterization (PSTC), consisting of the Dekati Gravimetric Impactor (DGI) and a porous tube diluter. Physico-chemical and toxicological properties of the particles emitted from various combustion sources were evaluated in two measurement campaigns. First, the DGI was compared with the High-Volume Cascade Impactor (HVCI) and to the Dekati Low-Pressure Impactor (DLPI), using the same dilution system and the same sampling conditions. Only small differences were observed in the mass size distributions, total particulate matter (PM), and particulate matter with diameter smaller than 1 um (PM(1)) concentrations and geometric mass mean diameters (GMMD) between these three impactors. Second, the PSTC was compared with the HVCI sampling system, which has been optimal for collection of particulate samples for toxicological and chemical analyses. Differences were observed in the mass size distributions, total PM and PM(1) emissions, and GMMDs, probably due to the different sampling and dilution methods as well as different sampling substrates which affected the behavior of semi-volatile and volatile organic compounds. However, no significant differences were detected in the in vitro measurements of cytotoxicity between the samples collected with the PSTC and the HVCI systems. In measurements of genotoxicity, significant differences between the two sampling systems were seen only with the particles emitted from the sauna stove. In conclusion, due to compact size, PSTC is an applicable method for use in particle sampling as part of the toxicological and chemical characterization of particulate emissions from different combustion sources. It offers some advantages compared to the previously used high-volume sampling methods including compactness for field measurements, simple preparation of sample substrates and high extraction efficiency"
Keywords:Air Pollutants/*chemistry/toxicity Analytic Sample Preparation Methods/instrumentation/*methods Animals Cell Cycle/drug effects Cell Line Cell Survival/drug effects Environmental Monitoring Humans Mice Mutagenicity Tests Particulate Matter/*chemistry/toxi;
Notes:"MedlineRuusunen, Jarno Tapanainen, Maija Sippula, Olli Jalava, Pasi I Lamberg, Heikki Nuutinen, Kati Tissari, Jarkko Ihalainen, Mika Kuuspalo, Kari Maki-Paakkanen, Jorma Hakulinen, Pasi Pennanen, Arto Teinila, Kimmo Makkonen, Ulla Salonen, Raimo O Hillamo, Risto Hirvonen, Maija-Riitta Jokiniemi, Jorma eng Evaluation Study Research Support, Non-U.S. Gov't Germany 2011/10/01 Anal Bioanal Chem. 2011 Dec; 401(10):3183-95. doi: 10.1007/s00216-011-5424-2. Epub 2011 Sep 30"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024