Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBiomarkers of Toxic Exposure and Oxidative Stress Among U.S. Adult Users of Premium Cigar Versus Other Cigar Subtypes: 2013-2019    Next Abstract"Cytochrome P450s from the Chinese white pine beetle, Dendroctonus armandi (Curculionidae: Scolytinae): Expression profiles of different stages and responses to host allelochemicals" »

Sci Rep


Title:A Novel Microwave-Induced Plasma Ionization Source for Ion Mobility Spectrometry
Author(s):Dai J; Zhao Z; Liang G; Duan Y;
Address:"Analytical and Testing Center, Sichuan University, Chengdu 610064, P.R. China. College of Chemical Engineering, Sichuan University, Chengdu 610065, P.R. China. College of Chemistry, Sichuan University, Chengdu 610065, P.R. China. Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610064, P.R. China"
Journal Title:Sci Rep
Year:2017
Volume:20170313
Issue:
Page Number:44051 -
DOI: 10.1038/srep44051
ISSN/ISBN:2045-2322 (Electronic) 2045-2322 (Linking)
Abstract:"This work demonstrates the application of a novel microwave induced plasma ionization (MIPI) source to ion mobility spectrometry (IMS). The MIPI source, called Surfatron, is composed of a copper cavity and a hollow quartz discharge tube. The ion mobility spectrum of synthetics air has a main peak with reduced mobility of 2.14 cm(2)V(-1)s(-1) for positive ion mode and 2.29 cm(2)V(-1)s(-1) for negative ion mode. The relative standard deviations (RSD) are 0.7% and 1.2% for positive and negative ion mode, respectively. The total ion current measured was more than 3.5 nA, which is much higher than that of the conventional (63)Ni source. This indicates that a better signal-to-noise ratio (SNR) can be acquired from the MIPI source. The SNR was 110 in the analysis of 500 pptv methyl tert-butyl ether (MTBE), resulting in the limit of detection (SNR = 3) of 14 pptv. The linear range covers close to 2.5 orders of magnitude in the detection of triethylamine with a concentration range from 500 pptv to 80 ppbv. Finally, this new MIPI-IMS was used to detect some volatile organic compounds, which demonstrated that the MIPI-IMS has great potential in monitoring pollutants in air"
Keywords:
Notes:"PubMed-not-MEDLINEDai, Jianxiong Zhao, Zhongjun Liang, Gaoling Duan, Yixiang eng Research Support, Non-U.S. Gov't England 2017/03/14 Sci Rep. 2017 Mar 13; 7:44051. doi: 10.1038/srep44051"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024