Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractThe preparation of trimethylsilyl derivatives of sodium salts of organic acids    Next AbstractRegulation of cyclin-substrate docking by a G1 arrest signaling pathway and the Cdk inhibitor Far1 »

J Environ Health Sci Eng


Title:Preparation of Carbotrap/silica composite for needle trap field sampling of halogenated volatile organic compounds followed by gas chromatography/mass spectrometry determination
Author(s):Poormohammadi A; Bahrami A; Ghiasvand A; Shahna FG; Farhadian M;
Address:"1Center of Excellence for Occupational Health, Research Center for Health Sciences, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran. GRID: grid.411950.8. ISNI: 0000 0004 0611 9280 2Department of Chemistry, Lorestan University, Khoramabad, Iran. GRID: grid.411406.6. ISNI: 0000 0004 1757 0173 3Centre of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran. GRID: grid.411950.8. ISNI: 0000 0004 0611 9280 4Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran. GRID: grid.411950.8. ISNI: 0000 0004 0611 9280"
Journal Title:J Environ Health Sci Eng
Year:2019
Volume:20191205
Issue:2
Page Number:1045 - 1053
DOI: 10.1007/s40201-019-00418-2
ISSN/ISBN:2052-336X (Print) 2052-336X (Electronic)
Abstract:"BACKGROUND: A needle trap device (NTD) was packed with Carbotrap/silica composite sorbent and applied for field sampling of halogenated volatile organic compounds (HVOCs) followed by gas chromatography/mass spectrometry (GC/MS) separation and determination. METHODS: Carbotrap B, as a highly pure surface sorbent, was prepared using sol-gel method to improve its surface properties for adsorption/desorption of the target analytes. The effects of important experimental variables on the sampling and determination of trichloroethylene (thrCE) and tetrachloroethylene (tetCE) using the proposed NTD-GC/MS strategy were evaluated and optimized. RESULTS: The results showed that sampling temperature and relative humidity interfered with sampling efficiency of the developed method and peak area responses of the analytes decreased with increasing temperature and relative humidity. The peak areas of the analytes increased with raising desorption temperature from 180 to 250 degrees C, and increasing desorption time from 1 to 3 min. The carryover experiments showed that the carryover effect disappeared after 3 min of desorption time. The Limits of Detection (LODs) and Limits of Quantitation (LOQs) of the analytes were in the range 0.01-0.03 and 0.05-0.09, respectively. CONCLUSIONS: The results indicated that the developed NTD-GC/MS procedure can be used as a technology with high sensitivity for the field sampling and determination of HVOCs"
Keywords:Air Carbotrap B Dry cleaning Needle trap device Silica;
Notes:"PubMed-not-MEDLINEPoormohammadi, Ali Bahrami, Abdulrahman Ghiasvand, Alireza Shahna, Farshid Ghorbani Farhadian, Maryam eng England 2020/02/08 J Environ Health Sci Eng. 2019 Dec 5; 17(2):1045-1053. doi: 10.1007/s40201-019-00418-2. eCollection 2019 Dec"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024