« Previous AbstractProfiling Volatile Constituents of Homemade Preserved Foods Prepared in Early 1950s South Dakota (USA) Using Solid-Phase Microextraction (SPME) with Gas Chromatography(-)Mass Spectrometry (GC-MS) Determination    Next AbstractTargeted Metabolic Profiling Indicates Apple Rootstock Genotype-Specific Differences in Primary and Secondary Metabolite Production and Validate Quantitative Contribution From Vegetative Growth »

Appl Occup Environ Hyg


Title:Working conditions and health in hairdressing salons
Author(s):Leino T; Kahkonen E; Saarinen L; Henriks-Eckerman ML; Paakkulainen H;
Address:"Department of Occupational Medicine, Finnish Institute of Occupational Health, Helsinki, Finland"
Journal Title:Appl Occup Environ Hyg
Year:1999
Volume:14
Issue:1
Page Number:26 - 33
DOI: 10.1080/104732299303386
ISSN/ISBN:1047-322X (Print) 1047-322X (Linking)
Abstract:"The purpose of the study was to assess the working conditions in hairdressing salons and the influence of work factors on the workers' health. Twenty randomly sampled hairdressing salons in the Helsinki, Finland, metropolitan area were selected for the study. The study was performed during winter 1994-1995; it included a survey of the hairdressing chemicals in use, the measurement of physical and chemical working conditions, and a self-administered questionnaire of the work environment and health of the workers. The air temperature varied between 16-25 degrees C, air velocity 0.02-0.3 m/s, and relative humidity, 18-42 percent. The total dust concentration varied between 66-133 micrograms/m3. The concentration of volatile organic compounds was 84-465 micrograms/m3 and the peaks rose to 25-45 mg/m3. The highest concentration of ammonia detected was 3.5 mg/m3. The long-term concentrations of thioglycolates and persulfates were at their lowest below the detection limit, and at their highest 1.8 micrograms/m3 for thioglycolates and 4.7 micrograms/m3 for persulfates, respectively, and the peaks of persulfates, 30 micrograms/m3. Hairdressing chemicals, awkward work postures, and repetitive movements were the most frequent causes of discomfort and for some had caused a work-related disease. Good general ventilation decreased the health complaints caused by hairdressing chemicals, but caused discomfort as a result of drafts. On average, the physical and chemical working conditions in the hairdressing salons were satisfactory compared with the Finnish criterion for indoor climate. However, the frequent high peak concentrations of chemicals during dyeing, bleaching, permanenting, and aerosol spraying still pose a significant health problem. Although effective general ventilation alleviated the effects of the air pollutants, it could not completely solve the problem. Therefore, local exhaust ventilation is recommended at the mixing places for hairdressing chemicals and wherever they are applied to the hair. According to our results, already increasing the air exchange rate up to 5 to 7 times per hour during the high exposure jobs would improve the situation"
Keywords:"Adolescent Adult Air Pollution, Indoor/*analysis Female Finland Hair Preparations/*adverse effects/chemistry Health Status Humans Male Middle Aged Occupational Exposure *Occupational Health Ventilation;"
Notes:"MedlineLeino, T Kahkonen, E Saarinen, L Henriks-Eckerman, M L Paakkulainen, H eng Research Support, Non-U.S. Gov't England 2000/03/24 Appl Occup Environ Hyg. 1999 Jan; 14(1):26-33. doi: 10.1080/104732299303386"

 