Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractTwo chemoreceptors mediate developmental effects of dauer pheromone in C. elegans    Next AbstractTemporal variability of indoor dust concentrations of semivolatile organic compounds »

Analyst


Title:Organic isocyanide-adsorbed gold nanostructure: a SERS sensory device for indirect peak-shift detection of volatile organic compounds
Author(s):Kim K; Lee JW; Shin D; Choi JY; Shin KS;
Address:"Department of Chemistry, Seoul National University, Seoul 151-742, Korea. kwankim@snu.ac.kr"
Journal Title:Analyst
Year:2012
Volume:20120307
Issue:8
Page Number:1930 - 1936
DOI: 10.1039/c2an16044g
ISSN/ISBN:1364-5528 (Electronic) 0003-2654 (Linking)
Abstract:"Organic isocyanide adsorbed on a noble metal nanostructure can be used as a platform for a volatile organic compound (VOC) sensor operating via surface-enhanced Raman scattering (SERS). This is possible since the NC stretching band of organic isocyanides such as 2,6-dimethylphenylisocyanide (2,6-DMPI) is very susceptible to the surface potential of Au onto which 2,6-DMPI is assembled. The surface potential of Au nanoparticles is even subject to change by VOCs, which can be easily monitored by the SERS of 2,6-DMPI. Thereby, under the flow of CCl(4) vapor at a partial pressure of 12.8 kPa, for instance, the NC stretching band is blue-shifted by up to 20 cm(-1) within 30 s, corresponding to a potential change of +0.56 V. Conversely, under the flow of butylamine at 12.8 kPa, the NC stretching band is red-shifted, instead of being blue-shifted, by as much as 12 cm(-1). At lower partial pressures, even a blue- or red-shift of 1 cm(-1) was reproducibly measured at a partial pressure of 125 mPa, corresponding to 6.5 ppm for CCl(4), suggesting that the present detection limit is superior to the results obtained via other techniques, especially those operating based on gold nanoparticles and aggregates"
Keywords:
Notes:"PubMed-not-MEDLINEKim, Kwan Lee, Ji Won Shin, Dongha Choi, Jeong-Yong Shin, Kuan Soo eng England 2012/03/08 Analyst. 2012 Apr 21; 137(8):1930-6. doi: 10.1039/c2an16044g. Epub 2012 Mar 7"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024