« Previous AbstractSuppression of Aflatoxin Biosynthesis in Aspergillus flavus by 2-Phenylethanol Is Associated with Stimulated Growth and Decreased Degradation of Branched-Chain Amino Acids    Next AbstractSimultaneous determination of four volatile compounds in rat plasma after oral administration of Shexiang Baoxin Pill (SBP) by HS-SPDE-GC-MS/MS and its application to pharmacokinetic studies »

Bioresour Technol


Title:Treatment of waste gas from the breather vent of a vertical fixed roof p-xylene storage tank by a trickle-bed air biofilter
Author(s):Chang S; Lu C; Hsu S; Lai HT; Shang WL; Chuang YS; Cho CH; Chen SH;
Address:"Department of Environmental Engineering, National Chung Hsing University, 402 Taichung City, Taiwan"
Journal Title:Bioresour Technol
Year:2011
Volume:20101028
Issue:2
Page Number:1028 - 1034
DOI: 10.1016/j.biortech.2010.09.106
ISSN/ISBN:1873-2976 (Electronic) 0960-8524 (Linking)
Abstract:"This study applied a pilot-scale trickle-bed air biofilter (TBAB) system for treating waste gas emitted from the breather vent of a vertical fixed roof storage tank containing p-xylene (p-X) liquid. The volatile organic compound (VOC) concentration of the waste gas was related to ambient temperature as well as solar radiation, peaking at above 6300 ppmv of p-X and 25000 ppmv of total hydrocarbons during the hours of 8 AM to 3 PM. When the activated carbon adsorber was employed as a VOC buffer, the peak waste gas VOC concentration was significantly reduced resulting in a stably and efficiently performing TBAB system. The pressure drop appeared to be low, reflecting that the TBAB system could be employed in the prolonged operation with a low running penalty. These advantages suggest that the TBAB system is a cost-effective treatment technology for VOC emission from a fixed roof storage tank"
Keywords:"*Air Biodegradation, Environmental Filtration/*instrumentation Gases/*isolation & purification Humidity Industrial Waste/analysis Pilot Projects Pressure Refuse Disposal/*instrumentation/*methods Seasons Temperature Time Factors Volatile Organic Compounds;"
Notes:"MedlineChang, Shenteng Lu, Chungsying Hsu, Shihchieh Lai, How-Tsan Shang, Wen-Lin Chuang, Yeong-Song Cho, Chi-Huang Chen, Sheng-Han eng Research Support, Non-U.S. Gov't England 2010/11/03 Bioresour Technol. 2011 Jan; 102(2):1028-34. doi: 10.1016/j.biortech.2010.09.106. Epub 2010 Oct 28"

 