Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSemivolatile organic compounds in window films from lower Manhattan after the September 11th World Trade Center attacks    Next AbstractThe role of Far1p in linking the heterotrimeric G protein to polarity establishment proteins during yeast mating »

J Chromatogr A


Title:"Safe Sampling Volume determinations of 12 volatile organic compounds on Carboxen 1003, Carbopack-X & Tenax-TA"
Author(s):Butterfield DM; Lipscombe RP; Gardiner TD;
Address:"Environment Department, National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, UK. Electronic address: david.butterfield@npl.co.uk. Environment Department, National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, UK. Electronic address: bob.lipscombe@npl.co.uk. Environment Department, National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, UK. Electronic address: tom.gardiner@npl.co.uk"
Journal Title:J Chromatogr A
Year:2020
Volume:20200624
Issue:
Page Number:461369 -
DOI: 10.1016/j.chroma.2020.461369
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"Pumped sorbent tube sampling is a well established method for the sampling of volatile organic compounds (VOCs) and semi volatile organic compounds (SVOCs) in ambient, indoor and workplace atmospheres(1). Safe sampling volumes and breakthrough volumes have been published for commonly found VOCs on widely used sorbents such as Tenax, however for newer sorbents and less commonly found VOCs there is less robust data. The Safe Sampling Volumes (SSVs) were determined from 15 tests of Retention Volume on 12 VOCs across the 3 sorbents. VOCs tested were: Aldehydes (C(5), C(6), C(8), C(9)), Ketones (C(4), C(6)), Alcohols (C(3), C(4)), Furan, Limonene, Isoprene and Ethyl Acetate. 12 VOC / sorbent combinations gave SSVs large enough for practical sampling of indoor atmospheres, while SSVs for Furan on Carbopack-X, Isovaleraldehyde on Tenax TA and Methyl Ethyl Ketone on Tenax TA gave SSVs that were too small to be of practical use. This work identifies suitable sorbents and sampling volumes for the complete range of species tested"
Keywords:"Adsorption Air Pollution, Indoor/analysis Aldehydes/chemistry Chromatography, Gas/*methods Environmental Monitoring Furans/chemistry Polymers/*chemistry Volatile Organic Compounds/*analysis/chemistry Ambient air Indoor air Pumped sampling Safe sampling vo;"
Notes:"MedlineButterfield, David M Lipscombe, Robert P Gardiner, Tom D eng Netherlands 2020/08/17 J Chromatogr A. 2020 Aug 30; 1626:461369. doi: 10.1016/j.chroma.2020.461369. Epub 2020 Jun 24"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024