« Previous AbstractDetermination of very volatile organic compounds in water samples by purge and trap analysis with a needle-type extraction device    Next AbstractNeedle extraction device for rapid and quantitative gas chromatographic determination of volatile chlorinated hydrocarbons and benzene in soil »

Anal Sci


Title:A Newly Designed Solid-Phase Extraction-type Collection Device for Precise Determination of Polycyclic Aromatic Hydrocarbons in Air
Author(s):Ueta I; Onikata M; Fujimura K; Yoshimura T; Narukami S; Mochizuki S; Sasaki T; Maeda T;
Address:"Department of Applied Chemistry, University of Yamanashi. Shinwa Chemical Industries Ltd. HORIBA STEC, Co. Ltd. National Institute of Advanced Industrial Science and Technology"
Journal Title:Anal Sci
Year:2017
Volume:33
Issue:10
Page Number:1175 - 1180
DOI: 10.2116/analsci.33.1175
ISSN/ISBN:1348-2246 (Electronic) 0910-6340 (Linking)
Abstract:"A newly designed styrene-divinylbenzene copolymer adsorbent packed solid-phase extraction (SPE)-type collection device for the quantitative determination of airborne polycyclic aromatic hydrocarbons (PAHs) containing two to five rings is reported in this manuscript. This SPE-type collection device offers rapid, easy and quantitative elution of the analytes and easier reuse. A small collection device was initially developed for investigating the basic collection and elution performances of the adsorbent with respect to PAHs. The analytes were quantitatively collected on the adsorbent up to 3 m(3) of air sampling at a sampling temperature of 35 degrees C. The collected analytes were then completely eluted from the adsorbent by passing 3 mL of dichloromethane without carry-over of the analyte. During air collection, because no moisture was trapped on the adsorbent, the subsequent gas chromatography-mass spectrometric analysis was not influenced by moisture. Based on these successful performances, a wide-bore collection device was introduced for collecting larger air samples. After a quantitative investigation of the collection and elution performances of the wide-bore collection device, it device was successfully applied for precise determinations of PAHs in atmospheric air. Further application and employment of the device for the precise determination of semi-volatile organic compounds in environmental air samples is expected due to these excellent results"
Keywords:Polycyclic aromatic hydrocarbon air pollutants sample preparation semi-volatile organic compounds;
Notes:"PubMed-not-MEDLINEUeta, Ikuo Onikata, Moe Fujimura, Koji Yoshimura, Tomotaka Narukami, Shoji Mochizuki, Suguru Sasaki, Tomohiro Maeda, Tsuneaki eng Switzerland 2017/10/11 Anal Sci. 2017; 33(10):1175-1180. doi: 10.2116/analsci.33.1175"

 