Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Annual transition and seasonal variation of indoor air pollution levels of 2-ethyl-1-hexanol in large-scale buildings in Nagoya, Japan"    Next Abstract"Characterization and source profiling of volatile organic compounds in indoor air of private residences in Selangor State, Malaysia" »

Nihon Koshu Eisei Zasshi


Title:[Indoor air pollution by volatile organic compounds in large buildings: pollution levels and remaining issues after revision of the Act on Maintenance of Sanitation in Buildings in 2002]
Author(s):Sakai K; Kamijima M; Shibata E; Ohno H; Nakajima T;
Address:Nagoya City Public Health Research Institute
Journal Title:Nihon Koshu Eisei Zasshi
Year:2010
Volume:57
Issue:9
Page Number:825 - 834
DOI:
ISSN/ISBN:0546-1766 (Print) 0546-1766 (Linking)
Abstract:"PURPOSE: This study aimed to clarify indoor air pollution levels of volatile organic compounds (VOCs), especially 2-ethyl-1-hexanol (2E1H) in large buildings after revising of the Act on Maintenance of Sanitation in Buildings in 2002. METHODS: We measured indoor air VOC concentrations in 57 (97%) out of a total of 61 large buildings completed within one year in half of the area of Nagoya, Japan, from 2003 through 2007. Airborne concentrations of 13 carbonyl compounds were determined with diffusion samplers and high-performance liquid chromatography, and of the other 32 VOCs with diffusion samplers and gas chromatography with a mass spectrometer. RESULTS: Formaldehyde was detected in all samples of indoor air but the concentrations were lower than the indoor air quality standard value set in Japan (100 microg/m3). Geometric mean concentrations of the other major VOCs, namely toluene, xylene, ethylbenzene, styrene, p-dichlorobenzene and acetaldehyde were also low. 2E1H was found to be one of the predominating VOCs in indoor air of large buildings. A few rooms in a small number of buildings surveyed showed high concentrations of 2E1H, while low concentrations were observed in most rooms of those buildings as well as in other buildings. It was estimated that about 310 buildings had high indoor air pollution levels of 2E1H, with increase during the 5 years from 2003 in Japan. CONCLUSIONS: Indoor air pollution levels of VOCs in new large buildings are generally good, although a few rooms in a small number of buildings showed high concentrations in 2E1H, a possible causative chemical in sick building symptoms. Therefore, 2E1H needs particular attention as an important indoor air pollutant"
Keywords:"Air Pollution, Indoor/*analysis/*legislation & jurisprudence Japan Volatile Organic Compounds/*analysis;"
Notes:"MedlineSakai, Kiyoshi Kamijima, Michihiro Shibata, Eiji Ohno, Hiroyuki Nakajima, Tamie jpn English Abstract Research Support, Non-U.S. Gov't Japan 2010/11/11 Nihon Koshu Eisei Zasshi. 2010 Sep; 57(9):825-34"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024