Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIntensification of volatile organic compounds mass transfer in a compact scrubber using the O3/H2O2 advanced oxidation process: kinetic study and hydroxyl radical tracking    Next Abstract"Identification of host blends that attract the African invasive fruit fly, Bactrocera invadens" »

Chemosphere


Title:Intensification of volatile organic compound absorption in a compact wet scrubber at co-current flow
Author(s):Biard PF; Couvert A; Renner C;
Address:"Ecole Nationale Superieure de Chimie de Rennes, CNRS, UMR 6226, 11 Allee de Beaulieu, CS 50837, 35708, Rennes Cedex 7, France. Electronic address: pierre-francois.biard@ensc-rennes.fr. Ecole Nationale Superieure de Chimie de Rennes, CNRS, UMR 6226, 11 Allee de Beaulieu, CS 50837, 35708, Rennes Cedex 7, France. Veolia Recherche et Innovation, Chemin de la Digue BP 76, 78603, Maisons Laffitte, France"
Journal Title:Chemosphere
Year:2017
Volume:20170116
Issue:
Page Number:612 - 621
DOI: 10.1016/j.chemosphere.2017.01.075
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"Three volatile organic compounds (VOC) with no acidic or basic function (butanol, butyraldehyde, methylethylketone), encountered at low concentrations in odorous effluents, were absorbed in water in a compact wet scrubber. This gas-liquid contactor consisted of a wire mesh packing structure where the gas phase flows at high velocity (>12 m s(-1)). A very turbulent two-phase downward flow could be observed in the scrubber with dispersed fine droplets (around 10 mum). For compounds showing a good affinity for water, such as butanol, removal efficiencies up to 90% were measured for a short contactor length of 32 cm leading to a gas residence time of 20 ms. However, the removal efficiency of butyraldehyde, which is poorly soluble in water, ranged between 10 and 30%. Mass-transfer modeling was achieved and underlined that working with several small scrubbers in series, fed with an unloaded solution, is effective to improve the removal efficiency. The influences of the VOC/solvent affinity, the contactor length, and the mass-transfer and hydrodynamic parameters on the removal efficiency were evaluated through a sensitivity analysis"
Keywords:Environmental Restoration and Remediation/instrumentation/*methods Equipment Design Volatile Organic Compounds/analysis/*isolation & purification/metabolism Waste Management/instrumentation/*methods Water/*chemistry Absorption Co-current Gas treatment Mas;
Notes:"MedlineBiard, Pierre-Francois Couvert, Annabelle Renner, Christophe eng England 2017/02/06 Chemosphere. 2017 Apr; 173:612-621. doi: 10.1016/j.chemosphere.2017.01.075. Epub 2017 Jan 16"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024