Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCognitive impairment and olfactory panic from occupational exposure to VOCs    Next AbstractCharacterization of selected organic compound classes in secondary organic aerosol from biogenic VOCs by HPLC/MSn »

Rapid Commun Mass Spectrom


Title:Gas chromatography/isotope ratio mass spectrometry of recalcitrant target compounds: performance of different combustion reactors and strategies for standardization
Author(s):Reinnicke S; Juchelka D; Steinbeiss S; Meyer A; Hilkert A; Elsner M;
Address:"Institute of Groundwater Ecology, Helmholtz Zentrum Muenchen, Ingolstaedter Landstr. 1, 85764, Neuherberg, Germany"
Journal Title:Rapid Commun Mass Spectrom
Year:2012
Volume:26
Issue:9
Page Number:1053 - 1060
DOI: 10.1002/rcm.6199
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Linking)
Abstract:"RATIONALE: Compound-specific isotope analysis (CSIA) relies on continuous flow combustion of organic substances to CO(2) and N(2) in a miniature reactor to measure (13)C/(12)C and (15)N/(14) N stable isotope ratios. Accurate analysis is well established for many volatile hydrocarbons. In contrast, compounds which contain hetero and halogen atoms are less volatile and may be more recalcitrant to combustion. METHODS: This study tested carbon and nitrogen isotope analysis of atrazine, desethylatrazine (DEA), dichlobenil and 2,6-dichlorobenzamide (BAM) by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) with multiple reactor tubes of two different kinds (conventional CuO/NiO/Pt and a NiO tube/CuO-NiO reactor prototype). RESULTS: The advantages of the NiO tube/CuO-NiO reactor were the absence of an additional reduction reactor, the possibility of routine reoxidation in nitrogen isotope analysis, and reliable atrazine and DEA measurements over several hundred injections. In contrast, BAM analysis showed good accuracy for carbon, but notable variations in the trueness of nitrogen isotope ratios. Accurate carbon and nitrogen analysis was nevertheless possible by bracketing samples with external compound-specific standards and subsequent offset correction. CONCLUSIONS: We conclude that instrument data should never be taken at its 'face value', but must consistently be validated with compound-specific standards of the respective analytes"
Keywords:
Notes:"PubMed-not-MEDLINEReinnicke, Sandra Juchelka, Dieter Steinbeiss, Sibylle Meyer, Armin Hilkert, Andreas Elsner, Martin eng England 2012/04/03 Rapid Commun Mass Spectrom. 2012 May 15; 26(9):1053-60. doi: 10.1002/rcm.6199"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 03-07-2024