Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBreath Collection from Children for Disease Biomarker Discovery    Next AbstractBreath Metabolites to Diagnose Infection »

Analyst


Title:Comparison of breath sampling methods: a post hoc analysis from observational cohort studies
Author(s):Berna AZ; Schaber CL; Bollinger LB; Mwale M; Mlotha-Mitole R; Trehan I; Odom John AR;
Address:"Department of Pediatrics, Washington University School of Medicine, St. Louis, MO 63110, USA. aodom@wustl.edu"
Journal Title:Analyst
Year:2019
Volume:144
Issue:6
Page Number:2026 - 2033
DOI: 10.1039/c8an01823e
ISSN/ISBN:1364-5528 (Electronic) 0003-2654 (Print) 0003-2654 (Linking)
Abstract:"In this report, we present a post hoc analysis from two observational cohorts, comparing the global breath volatile profile captured when using polymer sampling bags (mixed breath) versus Bio-VOC (alveolar breath). The cohorts were originally designed to characterize the breath volatile profiles of Malawian children with and without uncomplicated falciparum malaria. Children aged 3-15 years were recruited from ambulatory pediatric centers in Lilongwe, Malawi. Breath sampling was carried out two months apart (one study using a Bio-VOC and the second using sampling bags), and all samples were analyzed by gas chromatography/mass spectrometry. The efficacy of breath collection was assessed by quantifying levels of two high prevalence breath compounds, acetone and isoprene, as well as determining the overall number of breath compounds collected and their abundance. We found that the mean number of volatiles detected using sampling bags was substantially higher than when using the Bio-VOC (137 vs. 47). Breath collection by Bio-VOC also yielded reduced levels of endogenous breath volatiles, isoprene and acetone, even after breath volume correction. This suggests that the Bio-VOC dilutes the volatiles and introduces dead air or ambient air. Our results suggest that sampling bags are better suited for biomarker discovery and untargeted search of volatiles in pediatric populations, as evidenced by superior breath volatile detection"
Keywords:"Adolescent Biomarkers/*analysis Breath Tests/*methods Butadienes/analysis Child Child, Preschool Cohort Studies Gas Chromatography-Mass Spectrometry Hemiterpenes/analysis Humans Malaria, Falciparum/*diagnosis Plasmodium falciparum/*isolation & purificatio;"
Notes:"MedlineBerna, Amalia Z Schaber, Chad L Bollinger, Lucy B Mwale, Mwawi Mlotha-Mitole, Rachel Trehan, Indi Odom John, Audrey R eng R01 AI103280/AI/NIAID NIH HHS/ R21 AI123808/AI/NIAID NIH HHS/ R21 AI144472/AI/NIAID NIH HHS/ S10 RR026891/RR/NCRR NIH HHS/ Comparative Study Observational Study England 2019/02/01 Analyst. 2019 Mar 11; 144(6):2026-2033. doi: 10.1039/c8an01823e"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024