Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Human health risk evaluation of selected VOC, SVOC and particulate emissions from scented candles"    Next AbstractEffect of flotation and vegetal fining agents on the aromatic characteristics of Malvasia del Lazio (Vitis vinifera L.) wine »

Anal Chem


Title:Method for analysis of polar volatile trace components in aqueous samples by gas chromatography
Author(s):Pettersson J; Roeraade J;
Address:"Royal Institute of Technology, Department of Analytical Chemistry, SE-100 44 Stockholm, Sweden"
Journal Title:Anal Chem
Year:2005
Volume:77
Issue:10
Page Number:3365 - 3371
DOI: 10.1021/ac040170k
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"A new method has been developed for direct analysis of volatile polar trace compounds in aqueous samples by gas chromatography. Water samples are injected onto a short packed precolumn containing anhydrous lithium chloride. A capillary column is coupled in series with the prefractionation column for final separation of the analytes. The enrichment principle of the salt precolumn is reverse to the principles employed in conventional methods such as SPE or SPME in which a sorbent or adsorbent is utilized to trap or concentrate the analytes. Such methods are not efficient for highly polar compounds. In the LiCl precolumn concept, the water matrix is strongly retained on the hygroscopic salt, whereas polar as well as nonpolar volatile organic compounds show very low retention and are eluted ahead of the water. After transfer of the analytes to the capillary column, the retained bulk water is removed by backflushing the precolumn at elevated temperature. For direct injections of 120 microL of aqueous samples, the combined time for injection and preseparation is only 3.5 min. With this procedure, direct repetitive automated analyses of highly volatile polar compounds such as methanol or tetrahydrofuran can be performed, and a limit of quantification in the low parts-per-billion region utilizing a flame ionization detector is demonstrated"
Keywords:
Notes:"PubMed-not-MEDLINEPettersson, Johan Roeraade, Johan eng 2005/05/14 Anal Chem. 2005 May 15; 77(10):3365-71. doi: 10.1021/ac040170k"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024